12−19
EMISSION CONTROL
−
EGR SYSTEM (1KZ−TE)
1207N−01
INSPECTION
1.
(a)
ELECTRIC EGR CONTROL VALVE ASSY
Inspect the EGR valve operation.
(1) Under the condition of applying the vacuum to the
diaphragm chamber, check the valve operation.
Vacuum
EGR Valve
Less than 13 kPa (100 mmHg, 3.8 in.Hg)
Closed
More than 27 kPa (200 mmHg, 8.0 in.Hg)
Open
(2)
B12960
(3)
(b)
Ohmmeter
2
1
(2)
Apply vacuum to the diaphragm chamber and then
check each resistance between terminals of 3
(VOUT) and 2 (E2) of the lift sensor when the valve
is fully opened and also when fully closed.
Resistance:
2
Ohmmeter
B13119
Inspect the EGR lift sensor.
(1) Using an ohmmeter, check the resistance between
terminals 1 (VC) and 2 (E2) of the EGR lift sensor.
Resistance: 5.0 kW at 20_C (68_F)
A75981
B13118
3
When applying more than 67 kPa (500 mmHg, 19
in.Hg) of the vacuum, check if there is any leakage
of the vacuum.
Check the valve for sticking and heavy carbon deposits.
A75982
LAND CRUISER PRADO REPAIR MANUAL (RM990E)
EGR Valve
Resistance
Fully opened
4.2 kW at 20_C (68_F)
Fully closed
1.3 kW at 20_C (68_F)
HINT:
The resistance valve increases in proportion to the opening
angle of the EGR valve.
12−20
EMISSION CONTROL
Ohmmeter
−
EGR SYSTEM (1KZ−TE)
(c)
Inspect the E−VRV for open circuit.
(1) Using an ohmmeter, check that there is continuity
between the terminals.
Resistance: 11 − 13 W at 20_C (68_F)
(d)
Inspect the E−VRV for ground.
(1) Using an ohmmeter, check that there is no continuity between each terminal and the body.
Specified condition: No continuity
(e)
Inspect the E−VRV for air tightness.
(1) Check that when vacuum is applied to the vacuum
outlet port shown, the needle of the vacuum pump
indicates an increase of 47 kPa (350 mmHg, 13.9
in.Hg) or more.
(f)
Inspect the E−VRV operation.
(1) Apply about 6 V of DV power to the terminals.
(2) Check that when vacuum is applied to the vacuum
outlet port shown, the needle of the vacuum pump
does not move.
2.
(a)
VACUUM SWITCHING VALVE
Inspect the VSV for open circuit.
(1) Using an ohmmeter, check that there is continuity
between the terminals.
Resistance: 37 − 44 W at 20_C (68_F)
Continuity
B08927
Ohmmeter
No Continuity
B08928
Vacuum
B08929
Vacuum
6V
Y
B08930
Ohmmeter
Continuity
A70848
LAND CRUISER PRADO REPAIR MANUAL (RM990E)
12−21
EMISSION CONTROL
Ohmmeter
No Continuity
−
EGR SYSTEM (1KZ−TE)
(b)
Inspect the VSV for ground.
(1) Using an ohmmeter, check that there is no continuity between each terminal and the body.
Specified condition: No continuity
(c)
Inspect the VSV for air tightness.
(1) Check that when vacuum is applied to the vacuum
outlet port shown, the needle of the vacuum pump
indicates an increase of 47 kPa (350 mmHg, 13.9
in.Hg) or more.
(d)
Inspect the VSV operation.
(1) Apply about 12 V of DV power to the terminals.
(2) Check that when vacuum is applied to the vacuum
outlet port shown, the needle of the vacuum pump
does not move.
A70849
Vacuum
A70850
Vacuum
12V
A70851
LAND CRUISER PRADO REPAIR MANUAL (RM990E)