Official Software
Get notified when we add a new CadillacCTS Manual

We cover 60 Cadillac vehicles, were you looking for one of these?

2002-05 Cadillac Escalade Service & Repair Manual
Cadillac Srx Rwd Workshop Manual (V6-3.6L (2007))
Cadillac Deville Workshop Manual (V8-4.9L VIN B (1995))
Cadillac Srx Awd Workshop Manual (V6-3.6L (2008))
1999-2005--Cadillac--Deville DHS--8 Cylinders Y 4.6L MFI DOHC--32631401
Cadillac Srx 2wd Workshop Manual (V8-4.6L VIN A (2004))
Cadillac Srx Rwd Workshop Manual (V8-4.6L VIN A (2006))
1990-1998--Cadillac--Deville--8 Cylinders B 4.9L MFI OHV--31893201
Cadillac - Deville - Owners Manual - 1965 - 1965
Cadillac - Eldorado - Workshop Manual - 1996 - 2005
Cadillac - DTS - Workshop Manual - 2006 - 2007
1967-1989--Cadillac--Eldorado--8 Cylinders T 7.0L MFI OHV--31320102
Cadillac - ATS - Workshop Manual - 2008 - 2015
Cadillac - SRX - Workshop Manual - 2010 - 2012
1999-2005--Cadillac--Seville--8 Cylinders Y 4.6L MFI DOHC--32849002
1990-1998--Cadillac--Eldorado--8 Cylinders 3 4.5L MFI OHV--31003401
Cadillac - Escalade - Workshop Manual - (1982)
Cadillac - ATS - Workshop Manual - 2015 - 2016
1967-1989--Cadillac--Deville--8 Cylinders 8 4.1L TBI OHV--31168501
Cadillac - SRX - Workshop Manual - 2012 - 2015
1990-1998--Cadillac--Fleetwood Brougham--8 Cylinders P 5.7L MFI OHV--32000601
2006-2007--Cadillac--Escalade AWD--8 Cylinders 8 6.2L MFI OHV HO--33080001
Cadillac - Escalade - Workshop Manual - (2007)
1990-1998--Cadillac--Deville--8 Cylinders Y 4.6L MFI DOHC--32397101
1999-2005--Cadillac--Deville DTS--8 Cylinders 9 4.6L MFI DOHC HO--32587901
Cadillac - SRX - Workshop Manual - 2013 - 2013
Cadillac - SRX - Workshop Manual - 2010 - 2011
Cadillac - ATS - Workshop Manual - 2013 - 2013
1990-1998--Cadillac--Allante--8 Cylinders 8 4.5L MFI OHV--31751201
Cadillac - BLS - Workshop Manual - 2006 - 2006
1999-2005--Cadillac--Escalade--8 Cylinders R 5.7L MFI OHV--32528801
Cadillac - ATS - Workshop Manual - 2012 - 2013
1999-2005--Cadillac--Eldorado ESC--8 Cylinders Y 4.6L MFI DOHC--32711401
Cadillac - STS - Owners Manual - 2005 - 2005
Cadillac - Fleetwood - Workshop Manual - 1990 - 1998
1990-1998--Cadillac--Seville--8 Cylinders 3 4.5L MFI OHV--31003601
2004-2005--Cadillac--SRX AWD--8 Cylinders A 4.6L FI DOHC--32910902
1967-1989--Cadillac--Deville--8 Cylinders S 7.0L 4BL OHV--31299301
1990-1998--Cadillac--Seville STS--8 Cylinders 9 4.6L MFI DOHC HO--31954201
1967-1989--Cadillac--Eldorado--8 Cylinders S 7.0L 4BL OHV--31299401
Cadillac - Fleetwood - Owners Manual - 1954 - 1954
Cadillac - Deville - Workshop Manual - 1985 - 1993.PDF
1967-1989--Cadillac--Fleetwood--8 Cylinders S 7.0L 4BL OHV--31320201
Cadillac - STS-V - Owners Manual - 2008 - 2008 (German)
1967-1989--Cadillac--Deville--8 Cylinders 8 4.1L TBI OHV--31214702
1999-2005--Cadillac--Deville DTS--8 Cylinders 9 4.6L MFI DOHC HO--32711301
2004-2005--Cadillac--SRX 2WD--6 Cylinders 7 3.6L FI DOHC--32967601
Cadillac - Deville - Owners Manual - 1993 - 1993
1967-1989--Cadillac--Fleetwood Brougham--8 Cylinders R 7.7L 4BL OHV--31719301
Cadillac - Escalade - Workshop Manual - (1982)
2004-2005--Cadillac--SRX AWD--6 Cylinders 7 3.6L FI DOHC--32910901
1999-2005--Cadillac--Seville--8 Cylinders Y 4.6L MFI DOHC--32910601
1967-1989--Cadillac--Eldorado--8 Cylinders S 7.0L 4BL OHV--31320101
Cadillac - SLS - Workshop Manual - 1996 - 2002
Cadillac - SRX - Workshop Manual - 2005 - 2005
Cadillac - SRX - Owners Manual - 2011 - 2011
Cadillac - DTS - Owners Manual - 2008 - 2008
Cadillac - SRX - Workshop Manual - 2013 - 2014
1967-1989--Cadillac--Deville--8 Cylinders 6 6.0L 4BL OHV--31256603
1967-1989--Cadillac--Fleetwood Brougham--8 Cylinders 9 5.0L 4BL OHV HP--31091702
Summary of Content
2009-2015 Cadillac CTS-V Lingenfelter High Flow Intercooler Pump Upgrade Kit Installation Instructions (6.2L LSA Engine) PN: L330030709 Revision - 1.9 Lingenfelter Performance Engineering 1557 Winchester Road Decatur, IN 46733 (260) 724-2552 (260) 724-8761 fax www.lingenfelter.com Release date: 31 August 2016 Parts List Lingenfelter CTS-V High Flow Intercooler Pump Upgrade Kit (PN: L330030709) # Part number Description 1 2 1 2 2 2 2 1 1 1 TAFX410110 3177T62 XX00054-0002 47523 47213 47392 92510A494 XX05102-0015 12047835 L920010000 VariMax pump Clamp VariMax pump bracket M5x0.8x12mm Metric SS Socket Head Cap Screw M5x0.80 Metric Stainless Steel Nylon Insert Lock Nut M5 Metric Stainless Steel Flat Washer Unthreaded Spacer 3/4” OD, 5/16” Long, 3/8” Screw Size CTS-V to VariMax intercooler pump adapter harness Connector mounting clip Lingenfelter Decal Tools & Materials Required • • • • • • • Jack • 8mm wrench Jackstands or vehicle hoist • 13mm deep socket Hose clamp pliers (or equivalent) • 5/32” or 3mm Allen wrench Drain bucket (or equivalent) • Small pry tool or flat head screwdriver Ratchet • 50/50 DEX-COOL antifreeze Ratchet extension (if needed) • Sidecutters 3/4” Hose Plugs (x2) * These materials are used for installing the manual override switch only • Wire Strippers* 16 Gauge wire (orange)* • Crimpers* 15 amp rated switch* • • # Part number 1 2 2 L320030709 54205K11 7329K16 Optional Items Description CTS-V LSA intercooler radiator kit with fans Stainless Steel Constant tension worm gear clamp Spring clamp Thank you for purchasing the Lingenfelter Performance Engineering (LPE) VariMax CTS-V high flow intercooler pump upgrade kit. This kit is intended to bring the intercooler flow rate of the CTS-V up to the same flow rate as the ZL1 Camaro. As you can see in the chart provided on the next page, the factory CTS-V intercooler pump flows 25% less fluid per minute than the factory intercooler pump in the ZL1 Camaro. The VariMax intercooler pump, also shown in the chart on the next page, provides the same flow rate as the factory ZL1 Camaro intercooler pump. This kit is designed to provide easy mounting of the intercooler pump through a custom mounting bracket. Finally, this kit features a plug & play harness with an additional connector to allow for easy wiring of an optional manual override switch. Installing a manual override switch could be used to circulate the intercooler fluid between runs to help cool the fluid in drag racing applications. The Varimax CTS-V high flow intercooler pump is a DC brushless pump that has a soft start. The Varimax pump can accept a PWM speed control signal, but the way the CTS-V is wired the pump will always run at full speed. Being a soft start pump, the pump ramps up to full speed over time. A DC brushless pump does not have the initial current spike that a traditional pump will have. Read the entire instruction manual before beginning installation. Many of the stock parts will be used in reassembly. When referencing the side of the vehicle, the driver side of the vehicle is considered the left side and the passenger side of the vehicle is considered the right side of the vehicle. Due to the thermal expansion of rubber coolant hoses, LPE does not recommend using worm gear clamps to clamp the hoses to the intercooler pump. Because worm gear clamps do not apply constant tension to the hoses, the hoses can leak when exposed to cooler temperatures. LPE recommends the use of the OEM constant-tension clamps or spring clamps as superior alternatives to the standard worm gear clamp. Page 2 Page 3 Note: Some pictures show that the engine was removed from the vehicle. You do not need to remove your engine to install the Lingenfelter Performance Engineering (LPE) VariMax CTS-V high flow intercooler pump. 1. If you have been driving the vehicle, make sure to allow a couple hours for the engine to cool down before beginning installation. 2. Raise the vehicle with a vehicle hoist or a jack and jackstands. Be careful to follow the GM lifting procedures for the CTS-V. 3. In order to make it easier to drain the fluid from the system, remove the cap from the intercooler fluid reservoir. The reservoir is located at the back of the engine on the passenger side near the fire wall. Page 4 4. Locate the intercooler pump. This pump should be located just inside of the passenger side engine brace, just behind the radiator. 5. To drain the intercooler system of coolant, using a 3/8” square drive extension, remove the drain fitting from the passenger side of the intercooler radiator. Have a drain pan positioned to catch the fluid. Inspect the fluid. If it is normal in appearance, it can used again. If it is discolored then we recommend flushing the system of the old fluid and using all new intercooler fluid. 6. Using a pair of hose clamp pliers, loosen the hose clamp on the inlet hose. Disconnect the inlet hose from the intercooler pump and let both the pump and the hose drain into a bucket. Note: If the hose is difficult to remove, you can spray silicone in between the hose and the inlet of the pump. 7. Using a pair of hose clamp pliers, loosen the hose clamp on the outlet hose. Disconnect the outlet hose from the intercooler pump and let both the pump and the hose drain into a bucket. Note: If the hose is difficult to remove, you can spray silicone in between the hose and the outlet of the pump. Page 5 8. Locate the connector on the rear of the intercooler pump body and disconnect it by pinching the metal clips while pulling away from the pump. 9. Using a 13mm socket, ratchet, and extension if necessary, remove both M8 nuts that hold the Adel clamps to the factory mounting bracket. 10. Remove the intercooler pump from the mounting bracket, which will expose both M8 mounting studs, as well as the end of the wire loom retaining clip. 11. If you did not do so already, disconnect the harness connector that is located behind the factory intercooler pump mounting bracket. Page 6 12. Using hose plugs, cap off the intercooler hoses. 13. Using a small pry tool or flat head screwdriver, remove the wire loom retaining clip from the factory mounting bracket. The location of the wire loom retaining clip is shown by the red arrow in the adjacent illustration. Next, remove the factory intercooler pump harness from the vehicle. 14. Install the supplied wire loom retaining clip onto the supplied VariMax intercooler pump wiring harness by sliding it onto the connector, as shown by the red arrow in the adjacent illustration. 15. If a manual override switch is not being installed, install the plug seal into the end of the supplied connector, and close the retainer clip on the connector. Then install the connector onto the single connector that is on the harness. Page 7 16. If installing a manual override switch, crimp the female terminal onto 16 gauge wire and make sure the seal is crimped under the large tangs on the terminal. Then push to seat the terminal into the connector and close the retaining clip. Run the wire to a switch rated for at least 15 amps, and connect that switch to either an always hot, or accessory power source that uses a 15 amp fuse. 17. Install the new VariMax intercooler pump harness onto the factory intercooler pump mounting bracket by inserting the end of the wire loom retaining clip back into the bottom hole of the mounting bracket. Make sure to push the retaining clip through the hole as far as you can to ensure that the harness is securely fastened to the vehicle. 18. Plug the 2-way harness connector into the new VariMax intercooler pump harness. 19. Install the Varimax pump bracket (PN: XX000540002) onto the Varimax Pump as shown. Use an 8mm wrench and a 4mm (or 5/32”) Allen wrench to secure the bracket to the pump. Note: The bracket shown in steps 20-22 does not show the revision for the Christmas Tree fastener. The bracket fits over the Christmas Tree fastener without any modifications. Page 8 Order of Assembly is as follows: screw -> washer -> clamp -> bracket -> nut 20. Place the spacers onto the two studs that protrude out of the factory intercooler pump mounting bracket. 21. Place the VariMax intercooler pump bracket onto the two studs that protrude out of the factory intercooler pump mounting bracket as shown. Using a socket wrench and a 13mm deep socket, secure the Varimax intercooler pump bracket to the factory intercooler pump mounting bracket. 22. Plug the 4-way connector from adapter harness (PN: XX05102-0015) into the back of the VariMax intercooler pump. You should hear an audible “click” when the connector locking mechanism is fully engaged. Page 9 23. Remove the hose plug from the outlet hose. 24. Work the outlet hose onto the intercooler pump nipple that is pointing upward. Then, using a pair of hose clamp pliers, position and secure the hose clamp on the outlet hose. 25. Remove the hose plug from the inlet hose. 26. Work the inlet hose onto the intercooler pump nipple that is pointing towards the front of the vehicle. Then, using a pair of hose clamp pliers, position and secure the hose clamp on the inlet hose. Page 10 27. Verify the inlet and outlet hoses from the pump are not touching the fan shroud. FAN SHROUD 28. Fill the intercooler system using a 50/50 mixture of DEX-COOL antifreeze and clean, drinkable water until the coolant level reaches the top of the cold fill range on the reservoir. The location of the reservoir is shown by the yellow arrow in the adjacent illustration. NOTE - if the pump sound level changes or is erratic, you likely have air trapped in the system and need to bleed the system and make sure it is properly filled with coolant. It is very important to get all of the air out of the system. Installation of the Lingenfelter CTS-V VariMax high flow intercooler pump kit is now complete! NOTE: The Varimax CTS-V high flow intercooler pump is a DC brushless pump that has a soft start. The Varimax pump can accept a PWM speed control signal, but the way the CTS-V is wired the pump will always run at full speed. Being a soft start pump, the pump ramps up to full speed over time. A DC brushless pump does not have the initial current spike that a traditional pump will have. Page 11 NOTICES: It is the responsibility of the purchaser to follow all guidelines and safety procedures supplied with this product and any other manufacture’s product used with this product. Lingenfelter Performance Engineering assumes no responsibility for damages resulting from accident, improper installation, misuse, abuse, improper operation, lack of reasonable care, or all previously stated reasons due to incompatibility with other manufacturer’s products. Lingenfelter Performance Engineering assumes no responsibility or liability for damages incurred from the use of products manufactured or sold by Lingenfelter Performance Engineering on vehicles used for competition racing. It is the purchaser’s responsibility to check the state and local laws and sanctioning body requirements pertaining to the use of this product for racing applications. Lingenfelter Performance Engineering does not recommend nor condone the use of its products for illegal street racing. DISCLAIMER: The information provided in this document is intended for informational purposes only and is subject to change without notice. Lingenfelter Performance Engineering also reserves the right to make improvements and/or changes to the product described at any time without notice. For additional product installation information and technical support, contact Lingenfelter Performance Engineering or your Lingenfelter Performance Engineering products distributor. You can also find technical support and usage discussions regarding this product and many other Lingenfelter Performance Engineering products in our Internet forums: http://www.lingenfelter.com/forum_lingenfelter/index.php Join us on Facebook! http://www.facebook.com/#!/lpehp Lingenfelter Performance Engineering 1557 Winchester Road Decatur, IN 46733 (260) 724-2552 (260) 724-8761 fax www.lingenfelter.com L330030709 CTS-V high flow intercooler pump upgrade kit v1.9.indd Attachment A Page 13 Varimax Pump Data Sheet Specifications: VariMax: ORIENTATION REQUIREMENTS Pump Orientation: Pump Orientation Image Pump Orientation Run Condition OK Pump runs normally in these positions NOT GOOD Pump DOES NOT run normally in these positions Note: Attachment hoses should be fixed so as to not create an axial push/pull load on the pump. The pump should not be at the highest point within the coolant circuit to prevent air entrapment Page 14 PWM Frequency Diagram VariMax: PWM WAVE FREQUENCY (REFERENCE): Page 15 PIN#1:V_BAT + PIN#4:PWM OUTPUT 5V Scope CH2 MATES WITH: SUMITOMO SYSTEMS 91 SEALED SERIES STANDARD CONNECTOR F. FEMALE: RS04FG-GY PART# 6189-1105 (GREY) OR RS04 PART# 6189-0929 Scope CH1 10K Ohm - + + Function Gen - Normal Harness Hookup (5V) 13V PIN#4:PWM OUTPUT PIN#3:PWM INPUT 1 Pin Locations ©C ooper-Standard Au tomo tive VariMax: -ELECTRICAL CONNECTION PIN ASSIGNMENTS: Co nfidentia l In form ation PIN#2:GND PIN#1:V_BAT MATES WITH: SUMITOMO SYSTEMS 91 SEALED SERIES STANDARD CONNECTOR F. FEMALE: RS04FG-GY PART# 6189-1105 (GREY) OR RS04 PART# 6189-0929 Normal Harness Hookup (5V) Scope CH1 + Function Gen - Page 16 VariMax: Simplifed Operation Diagram VariMax: Simplifed Operation Diagram Operational Diagram Page 17 VariMax: PWM 'in' diagram PWM IN Page 18 VariMax: PWM 'out' diagram PWM OUT Pump Warning 4 - 6% A) Low Back EMF (possible impeller blockage) – Stops forward rotation, reverses the motor for 2.5s to clear potential impeller blockage, and then restarts. B) High temperature warning (Temperature is close to operational thermal limit) Motor slows to 2500RPM, in an attempt to cool. The lower RPM lowers the current which in turn, lowers the pump self heating characteristic. The pump exits this mode once the temperature (warning condition) has moved below the full operation temperature limit (timing is unspecified). C) Over-Current during normal operation (possible problem) - If an over-current occurs during normal operation the pump is stopped. After a 10 second wait, the pump will attempt to restart. Pump Fault 88-90% A) Impeller Blockage (sustained Low back EMF) - If 5 consecutive blockage events (see Pump Warning “A” low back EMF) have occurred, this mode is entered. The pump will stop. The pump will not restart until a power re-cycle occurs. B) Over Temperature - The high temperature operation limit is exceeded. The pump stops and stays in this state until the unit cools. C) Over-Current at startup - if an over-current occurs during initial activation of FETS, the pump is stopped until a power re-cycle occurs. D) Over-Current during operation (sustained over-current during operation) - After 5 consecutive cycles of “Over-Current during normal operation” (See Pump Warning “C”), the pump is stopped until a power re-cycle occurs.