Water Heater
Thermo Top Evo Parking Heater
E1
00 0258
Installation Documentation
Ford Focus / C-Max / Grand C-Max
Validity
Manufacturer
Ford
Ford
Ford
Model
C-Max
C-Max / Grand C-Max
Focus
Type
DXA
DXA
DYB
EG-BE-No. / ABE
e13 * 2007 / 46 * 1103 * ...
e13 * 2007 / 46 * 1103 * ...
e13 * 2007 / 46 * 1138 * ...
Ford Focus
Motorisation
1.0 EcoBoost
1.0 EcoBoost
1.6 Duratec
1.6 Duratec
1.6 Duratec
Fuel
Petrol
Petrol
Petrol
Petrol
Petrol
Transmission type Output in kW
SG
74
SG
92
SG
77
SG
92
SG
110
Displacement in cm³
998
998
1560
1560
1560
Engine code
M2DA
M1DA
IQ
PN
JQ
Transmission type Output in kW
SG
77
SG
92
SG
110
Displacement in cm³
1560
1560
1560
Engine code
IQ
PN
JQ
Ford C-Max / Grand C-Max
Motorisation
1.6 Duratec
1.6 Duratec
1.6 Duratec
Fuel
Petrol
Petrol
Petrol
SG = manual transmission
From Model Year 2011
Left-hand drive vehicle
Verified equipment variants: Manual air-conditioning (Focus only) / Automatic air-conditioning
Front fog light
automatic Start-Stop system
Not verified:
Passenger compartment monitoring
Exclusion:
Not for 1.6 EcoBoost from model year 2012!
Total installation time:
approx. 8 hours
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE
Ford Focus / C-Max / Grand C-Max
Table of Contents
Validity
1
Necessary Components
2
Installation Overview
2
Information on Total Installation Time
2
Information on Operating and Installation Instructions 3
Information on Validity
4
Technical Information
4
Explanatory Notes on Document
4
Preliminary Work
5
Heater Installation Location
5
Preparing Electrical System
6
Electrical System
7
Fan Controller for Manual Air-Conditioning
9
Fan Controller for Automatic Air-Conditioning
11
Option (Telestart)
14
Preparing Installation Location
Preparing Heater
Installing Heater
Fuel
Combustion Air
Exhaust Gas
Coolant Circuit
Final Work
Operating Instructions for Manual A/C Focus
Operating Instructions for Automatic A/C Focus
Operating Instructions for Automatic A/C C-Max / Grand C-Max
16
18
19
21
26
27
30
34
35
36
37
Necessary Components
• Basic delivery scope Thermo Top Evo in accordance with price list
• Installation kit for Ford Focus / C-Max / Grand C-Max 2011 Petrol: 1316972A
• Heater control in accordance with price list and upon consultation with end customer
• Extension of clock wiring harness (additionally for the installation of the digital timer): 70813B
• In case of Telestart, indicator lamp in accordance with price list and in consultation with end
customer
Note
To facilitate the work, the vehicle should only be delivered with a 1/4 filled tank!
Installation Overview
Legend:
1
1. Heater
2. Engine compartment fuse holder
3. Passenger compartment fuse
holder manual air-conditioning
and automatic air-conditioning
for Focus
4. Passenger compartment fuse
holder automatic air-conditioning for C-Max / Grand C-Max
5. Circulating pump
6. Digital timer
7. Metering pump
3
7
4
5
6
2
Information on Total Installation Time
The total installation time includes the time needed for mounting and demounting of the vehicle-specific components,
the heater specific installation time and all other times required for the system integration and initial start-up of the
heater.
The total installation time may vary for vehicle equipment other than provided.
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE
2
Ford Focus / C-Max / Grand C-Max
Information on Operating and Installation Instructions
1
Important Information (not complete)
Beginning of excerpt.
1.1
Installation and Repair
ANNEX VII
The improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly carbon monoxide, leading
to serious injury or death.
REQUIREMENTS FOR COMBUSTION HEATERS AND THEIR INSTALLATION
1.
GENERAL REQUIREMENTS
1.7.1.
A clearly visible tell-tale in the operator's field of view shall inform when
the combustion heater is switched on or off.
2.
VEHICLE INSTALLATION REQUIREMENTS
2.1.
Scope
2.1.1.
Subject to paragraph 2.1.2. combustion heaters shall be installed according to the requirements of this Annex.
Only use genuine Webasto parts. See the Webasto air and water heaters accessories catalogue for this purpose.
2.1.2.
Vehicles of category O having liquid fuel heaters are deemed to comply
with the requirements of this Annex.
1.2
2.2.
Positioning of heater
To ensure safe operation, we recommend having the heater checked every two
years by an authorised Webasto dealer, especially when used over a long period
and/or under extreme environmental conditions.
2.2.1.
Body sections and any other components in the vicinity of the heater
must be protected from excessive heat and the possibility of fuel or oil
contamination.
Do not operate the heater in closed rooms due to the danger of poisoning and suffocation.
2.2.2.
The combustion heater shall not constitute a risk of fire, even in the case
of overheating. This requirement shall be deemed to be fulfilled if the installation ensures an adequate distance to all parts and suitable ventilation, by the use of fire resistant materials or by the use of heat shields.
2.2.3.
In the case of M2 and M3 vehicles, the heater must not be positioned in
the passenger compartment. However, an installation in an effectively
sealed envelope which also complies with the conditions in paragraph
2.2.2 may be used.
To install and repair Webasto heating and cooling systems you need to
have completed a special company training course and have the appropriate technical documentation, special tools and special equipment.
Installation and repair may ONLY be carried out by persons trained and
certified in a Webasto training course. NEVER try to install or repair Webasto heating or cooling systems if you have not completed a Webasto
training course, you do not have the necessary technical skills and you
do not have the technical documentation, tools and equipment available
to ensure that you can complete the installation and repair work properly.
Operation
Always switch off the heater before refuelling.
The heater may only be used with the prescribed fuel Diesel (DIN EN 590) or petrol (DIN EN 227).
The heater may not be cleaned with a high-pressure cleaner.
1.3
Please note
2.2.4.
ALWAYS follow all Webasto installation and operating instructions and observe all
warnings.
The label referred to in paragraph 1.4 or a duplicate, must be positioned
so that it can be easily read when the heater is installed in the vehicle.
2.2.5.
To become familiar with and understand all functions and properties of the heater,
the operating instructions must be read carefully and observed at all times.
Every reasonable precaution should be taken in positioning the heater
to minimise the risk of injury and damage to personal property.
2.3.
Fuel supply
2.3.1.
The fuel filler must not be situated in the passenger compartment and
must be provided with an effective cap to prevent fuel spillage.
2.3.2.
In the case of liquid fuel heaters, where a supply separate to that of the
vehicle is provided, the type of fuel and its filler point must be clearly labelled.
Webasto shall assume no liability for defects, damage and injuries resulting
from a failure to observe the installation, repair and operating instructions
of the information contained in them.
2.3.3.
A notice, indicating that the heater must be shut down before refuelling,
must be affixed to the fuelling point. In addition a suitable instruction
must be included in the manufacturer's operating manual.
This liability exclusion particularly applies to improper installations and repairs, installations and repairs by untrained persons or in the case of a failure to use genuine spare parts.
2.4.
Exhaust system
2.4.1.
The exhaust outlet must be located so as to prevent emissions from entering the vehicle through ventilators, heated air inlets or opening windows.
2.5.
Combustion air inlet
2.5.1.
The air for the combustion chamber of the heater must not be drawn
from the passenger compartment of the vehicle.
2.5.2.
The air inlet must be so positioned or guarded that blocking by rubbish
or luggage is unlikely.
For proper, safe installation and repair work, the installation instructions with all
warnings and safety information must be carefully read and observed at all times.
Please always contact a workshop authorised by Webasto for all installation and
repair work.
IMPORTANT
The liability due to culpable disregard to life, limb or health and due to damage or injuries caused by a wilful or reckless breach of duty remain unaffected, as does the obligatory product liability.
Installation should be carried out according to the general, standard rules
of technology. Unless specified otherwise, fasten hoses, lines and wiring
harnesses to original vehicle lines and wiring harnesses using cable ties.
Insulate loose wire ends and tie back.
Sharp edges should be fitted with rub protection (split-open fuel hose)!
Spray unfinished body areas, e.g. drilled holes, with anti-corrosion wax
(Tectyl 100K, Order No. 111329).
2.6.
Heating air inlet
2.6.1.
The initial startup is to be executed with the Webasto Thermo Test Diagnosis.
The heating air supply may be fresh or recirculated air and must be
drawn from a clean area not likely to be contaminated by exhaust fumes
emitted either by the propulsion engine, the combustion heater or any
other vehicle source.
2.6.2.
The inlet duct must be protected by mesh or other suitable means.
When installing an IPCU, the corresponding settings must be checked or
adjusted before the installation.
2.7.
Heating air outlet
2.7.1.
Any ducting used to route the hot air through the vehicle must be so positioned or protected that no injury or damage could be caused if it were
to be touched.
2.7.2.
The air outlet must be so positioned or guarded that blocking by rubbish
or luggage is unlikely.
Observe the instructions and guidelines of the respective vehicle manufacturer for demounting and mounting vehicle specific components!
2
Statutory regulations governing installation
Guidelines
Thermo Top Evo
Heating Directive ECE R122
EMC Directive ECE R10
E1 00 0258
E1 03 5627
NOTE
End of excerpt.
In multilingual versions the German language is binding.
The regulations of these guidelines are binding in the scope of the Directive
70/156/EEC and/or 2007/46/EC (for new vehicle models from 29/04/2009) and
should also be observed in countries in which there are no special regulations.
IMPORTANT
Failure to follow the installation instructions will result in the invalidation of the type
approval for the heater and therefore invalidation of the general homologation of
the vehicle.
NOTE
For vehicles with an EU permit, no entry in accordance with § 19 Sub-Section 4
of Annex VIII b to the Road Traffic Act is required.
2.1
Excerpt from the directive 2001/56/EC Appendix VII for the
installation of the heater
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE
3
Ford Focus / C-Max / Grand C-Max
Information on Validity
This installation documentation applies to Ford Focus / C-Max / Grand C-Max Petrol vehicles - for validity, see
page 2 - from model year 2011 and later, assuming technical modifications to the vehicle do not affect installation,
any liability claims excluded. Depending on the vehicle version and equipment, modifications may be necessary during installation with respect to this installation documentation.
Vehicle and engine types, equipment variants and specifications not listed in this installation documentation have not
been tested. However, installation according to this installation documentation may be possible.
Technical Information
Special Tools
• Hose clamp pliers for self-clamping hose clamps
• Hose clamp pliers for Clic hose clamps of type W
• Automatic wire stripper 0.2 - 6mm²
• Crimping pliers for cable lug / tab connector 0.5 - 6mm²
• Torque wrench for 2.0 - 10 Nm
• Hose clamping pliers
• Metric thread-setter kit
• Webasto Thermo Test diagnosis with current software
Dimensions
• All dimensions are in mm.
Tightening torque values
• Tightening torque values of 5x13 heater bolts = 8Nm.
• Tightening torque values of 5x15 retaining plate of water connection piece bolts = 7Nm.
• Tighten other bolt connections in accordance with manufacturer's instructions or in accordance with
state-of-the-art- technology.
Explanatory Notes on Document
You will find an identification mark on the outside
top right corner of the page in question to provide
you with a quick overview of the individual working
steps.
Special features are highlighted using the following symbols:
Mechanical system
Specific risk of injury or
fatal accidents
Electrical system
Specific risk of damage to
components
Coolant circuit
Specific risk of fire or explosion
Combustion air
Reference to general installation instructions
of the Webasto components or to the
manufacturer's vehicle-specific documents
Fuel
Exhaust gas
Reference to a special technical feature
The arrow in the vehicle icon
indicates the position on the vehicle
and the viewing angle
Software
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE
4
Ford Focus / C-Max / Grand C-Max
Preliminary Work
Vehicle
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Open the fuel tank cap.
Ventilate the fuel tank.
Close the fuel tank cap again.
Depressurise the cooling system.
Disconnect and remove the battery.
Remove the engine cover.
Remove the windscreen wiper.
Remove the cover of the coolant reservoir.
Remove the cover of the coolant reservoir for the engine compartment.
Drain the coolant according to the manufacturer's instructions.
Remove the intake manifold.
Remove the engine underride protection.
Remove the underbody trim on the right next to the tank.
Detach the heat protection trim of the exhaust system in the area of the tank.
Remove the tank according to the manufacturer's instructions.
Remove the footwell trim on the front passenger's side.
Remove the glove compartment.
Remove the shift lever trim.
Remove the trim of the centre console.
Remove the A/C control panel in accordance with the manufacturer's instructions.
Remove the A-pillar trim of the footwell on the front passenger's side (only with Telestart).
Heater
• Remove years that do not apply from the type and duplicate label.
• Attach the duplicate label (type label) at the appropriate place in the engine compartment.
Heater Installation Location
1
1 Heater
Installation
location
1
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE
5
Ford Focus / C-Max / Grand C-Max
Preparing Electrical System
rt/sw
rt
gn/ws
0,5²
4²
0,75²
Wire sections retain their numbering in the
entire document.
F3
F4
All equipment
Inserting
F4,
Connect wires to socket of K1 relay. Insert
preparing
25A fuse F4. K1 relay is inserted only after in- K1 relay
stalling the fuse holder.
1
86
87
85
30
87a
K1
Red (rt) wire 4²
Black (sw) wire 4²
br
2
0,5²
Automatic air-conditioning
5
Cutting
wires to
length
3
rt
0,5²
500
1000
Connect wires to IPCU socket.
IPCU view on contact side.
The IPCU included in the kit is pre-programmed with the following settings:
5
4
15
A
86
IPCU
15
A
85
E
E
86
7
85
3
6
Duty cycle:
Frequency:
Voltage:
Function:
37%
400Hz
3.6V
Low side
Premounting IPCU
Red (rt) wire 0.5²
Black (sw) wire 0.5²
Red (rt) wire 0.5²
Brown (br) wire 0.5²
Green/white (gn/ws) wire 0.5²
The settings are to be checked during the
function check on the vehicle, and adjusted if
necessary.
Pull wires 3 and 4 into the attached protective
sleeving.
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE
6
Ford Focus / C-Max / Grand C-Max
Electrical System
Focus
Plus and earth wire
Wiring harness pass through
1 Earth wire, 8 mm dia. cable lug at original vehicle earth support point
2 Positive wire on positive battery terminal
1 Protective rubber plug
1
1
2
2
3
Wiring harness routing
diagram
(manual
air-conditioning)
Do not install the metering pump
wiring harness until later together with fuel line along the original
vehicle fuel lines on the underbody
2
1
4
1
3
4
Digital timer
Fuse holder of engine compartment
1 Angle bracket
2 M5x16 bolt, large diameter washer [2x], retaining plate of fuse holder, nut
3 Fuses F1-2
4 M6x20 bolt, flanged nut, existing hole
Ident. No.: 1316973E_EN
5
Use clock cable extension when installing digital
timer.
1 Digital timer
Status: 02.01.2013
© Webasto Thermo & Comfort SE
7
Ford Focus / C-Max / Grand C-Max
C-Max / Grand C-Max
Plus and earth wire
Wiring harness pass through
1 Earth wire, 8 mm dia. cable lug at original vehicle earth support point
2 Positive wire on positive battery terminal
1 Protective rubber plug
1
1
2
6
7
Wiring harness routing
diagram
Do not install the metering pump
wiring harness until later together with fuel line along the original
vehicle fuel lines on the underbody
1
1
2
8
9
Fuse holder of engine compartment
Digital timer
When drilling, pay attention to components located behind.
Use clock cable extension when installing digital
timer.
1 5.5mm dia. hole, M5x16 bolt, large diameter
washer, retaining plate of fuse holder, nut
2 Fuses F1-2
Ident. No.: 1316973E_EN
1 Digital timer
Status: 02.01.2013
© Webasto Thermo & Comfort SE
8
Ford Focus / C-Max / Grand C-Max
Fan Controller for Manual Air-Conditioning
Webasto
Ford
30
15
HG
F2
F1
1
X2
2 2
5
X1
F10
F23
ge
R13
0,5²
rt/sw
0,5²
Wiring diagram
PF3
rt
gn/ws
4²
0,75²
br
rt/sw
rt
gn/ws
0,5²
0,5²
4²
0,75²
C21
gr/
vi
2H403
rt
4²
X10
F3
F4
1
86
87
br
0,5²
1
2
C2
4
3
2
1
C1
gr/
vi
B
30
M
br
0,5²
3
87a
K1
85
4
2
2H123
sw
4²
2H105
5
C1
31
Webasto components
HG
Heater TT-Evo
X1
6-pin heater connector
X2
2-pin heater connector
X10
4-pin connector
Heater control
K1
Fan relay
F1
20A fuse
F2
30A fuse
F3
1A fuse
F4
25A fuse
Ident. No.: 1316973E_EN
Vehicle components
2H403
Resistor group
C2
Connector 2H403
2H123
Fan motor
B
Connector 2H123
2H105
Fan switch
C1
Connector 2H426
C21
Socket connection
R13
Fan relay
PF3
100A fuse
F10
40A fuse
F23
5A fuse
Status: 02.01.2013
Colours and symbols
rt
red
sw
black
ge
yellow
gn
green
or
orange
ws
white
br
brown
gr
grey
vi
violet
Legend
X
Cutting point
Wiring colours may vary.
© Webasto Thermo & Comfort SE
9
Ford Focus / C-Max / Grand C-Max
Focus
1
1 6.5 mm dia. hole
Hole for
passenger
compartment fuse
holder
10
10
1
Mount K1 relay 5 after installation.
2
3
1 M5x16 bolt, large diameter washer [2x],
nut
2 Angle bracket
3 M6x20 bolt, flanged nut
4 Fuse holder of passenger compartment
5
Mounting
fuse holder
of passenger compartment
11
4
1
2
Produce connections as shown in wiring diagram. Connect wiring harness of passenger
compartment fuse holder 2 to wiring harness
of heater 1 according to wiring diagram, in
such a way that wires of the same colour are
connected to each other.
Connecting wiring
harnesses
12
Connect to socket connector C21 3 pin 1 before the fan motor.
Produce connections as shown in wiring diagram.
1
3
1 Grey/violet (gr/vi) wire of fan motor 2H123
2 Grey/violet (gr/vi) wire of fan relay R13
Red (rt) wire of K1/87a
Black (sw) wire of K1/30
2
1
Ident. No.: 1316973E_EN
2
Connecting fan motor
13
Status: 02.01.2013
© Webasto Thermo & Comfort SE 10
Ford Focus / C-Max / Grand C-Max
Fan Controller for Automatic Air-Conditioning
Webasto
Ford
30
15
HG
F2
1
X2
F1
2 2
5
F10
F23
X1
Wiring diagram
PF3
R13
ge
gr/vi
0,5²
C21
rt/sw
0,5²
rt
gn/ws
4²
0,75²
gr/
or
rt
4²
gn/ws
br
0,5²
rt/sw
rt
gn/ws
0,5²
4²
0,75²
F3
F4
X10
sw
0,5²
4²
gr/
or
C1
2
2H102
1
86
87
87a
C3
K1
85
br
br
0,5²
0,5²
3
4
1
2
sw
30
0,5²
rt
2
0,5²
7
IPCU
86
A
ws/
vi
B
4
E
M
3
br
0,5²
85
6
ws/
vi
15
5
C2
2H123
15
6
2H101
rt
0,5²
31
Webasto components
HG
Heater TT-Evo
X1
6-pin heater connector
X2
2-pin heater connector
X10
4-pin connector
Heater control
K1
Fan relay
F1
20A fuse
F2
30A fuse
F3
1A fuse
F4
25A fuse
IPCU Pulse width modulator
IPCU settings:
Duty cycle: 37%
Frequency: 400Hz
Voltage:
3.6V
Function:
Low side
Ident. No.: 1316973E_EN
Vehicle components
2H102
Fan controller
C1
Connector 2H102
C3
Connector 2H102
2H123
Fan motor
B
Connector 2H123
2H101
A/C control unit
C2
Connector 2H101
C21
Socket connection
R13
Fan relay
PF3
100A fuse
F10
40A fuse
F23
5A fuse
Colours and symbols
rt
red
sw
black
ge
yellow
gn
green
br
brown
ws
white
gr
grey
vi
violet
Legend
X
Cutting point
Wiring colours may vary.
Status: 02.01.2013
© Webasto Thermo & Comfort SE 11
Ford Focus / C-Max / Grand C-Max
1
Focus
2
1 M5x16 bolt, large diameter washer [2x],
nut
2 Angle bracket
3 Fuse and relay socket
4 Mount IPCU socket
Premounting K1 relay
4
3
14
1 M6x20 bolt, flanged nut
Mounting
fuse holder
of passenger compartment
1
15
1
2
5
16
Connect to socket connector C21 1 Pin 1 before the fan controller. Produce connections
as shown in wiring diagram.
1
2
1
2
Ident. No.: 1316973E_EN
Produce connections as shown in wiring diagram. Connect wiring harness of passenger
compartment fuse holder 2 to wiring harness
of heater 1 according to wiring diagram, in
such a way that wires of the same colour are
connected to each other.
Connecting wiring
harnesses
3
2 Green/orange (gr/or) wire of fan relay R13
3 Green/orange (gr/or) wire of fan control- Connectler 2H102
ing fan con Red (rt) wire of K1/87a
troller
Black (sw) wire of K1/30
Red (rt) wire of IPCU/15
17
Status: 02.01.2013
© Webasto Thermo & Comfort SE 12
Ford Focus / C-Max / Grand C-Max
Connect to connector C2 3 Pin 15 from A/C
control unit. Produce connections as shown
in wiring diagram.
1
4
3
2
1 White/violet (ws/vi) wire of fan controller 2H102
2 White/violet (ws/vi) wire of connector C2,
Pin 15
Red (rt) wire of IPCU/E
Black (sw) wire of IPCU/A
Connecting A/C
control unit
18
3
C-Max and Grand C-Max
1
Engage fuse holder of passenger compartment 2 in IPCU socket 3.
2
1 M5x16 bolt, large diameter washer, exist- Mounting
ing threaded hole
fuse holder
of passenger compartment
19
3
1 K1 relay
Mounting
K1 relay
1
20
1
2
7
6
Ident. No.: 1316973E_EN
Produce connections as shown in wiring diagram. Connect wiring harness of passenger
compartment fuse holder 2 to wiring harness
of heater 1 according to wiring diagram, in
such a way that wires of the same colour are
connected to each other.
Connecting wiring
Brown (br) wire of IPCU/85
harnesses
Green/white (gn/ws) wire of IPCU/86
21
Status: 02.01.2013
© Webasto Thermo & Comfort SE 13
Ford Focus / C-Max / Grand C-Max
1
Connect to socket connector C21 3 Pin 24
before the fan controller.
Produce connections as shown in wiring diagram.
2
1 Green/violet (gr/vi) wire of fan controller 2H102
2 Grey/violet (gr/vi) wire of fan relay R13
Red (rt) wire of K1/87a
Black (sw) wire of K1/30
Red (rt) wire of IPCU/15
3
2
5
1
22
1
4
Connect to connector C2 3 Pin 15 from A/C
control unit.
Produce connections as shown in wiring diagram.
1 White/violet (ws/vi) wire of fan controller 2H102
2 White/violet (ws/vi) wire of connector C2,
Pin 15
Red (rt) wire of IPCU/E
Black (sw) wire of IPCU/A
3
2
3
Connecting fan controller
Connecting A/C
control unit
23
Remote Option (Telestart)
1
C-Max / Grand C-Max
Fasten receiver 1 with adhesive tape.
Mounting
receiver
24
1 Antenna
1
Mounting
antenna
25
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 14
Ford Focus / C-Max / Grand C-Max
Focus
1
Angle down bracket of receiver 2 as shown.
2
3
1 M6x20 bolt, flanged nut, existing hole
3 Receiver
Mounting
receiver
26
1 Antenna
1
Mounting
antenna
27
Temperature sensor T100 HTM
1
All vehicles
2
Fasten temperature sensor 2 with cable tie 1
to original vehicle wiring harness.
Mounting
temperature sensor
28
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 15
Ford Focus / C-Max / Grand C-Max
1
Preparing Installation Location
2
C-Max / Grand C-Max
Remove insulating tape 1 from original vehicle wiring harness, uncover connector.
2 Remove cable tie (cable bracket)
Preparing
installation
location
29
1
Wind connector 2 with insulation strips and
fasten with cable tie 1 to original vehicle wiring harness.
2
Tying back
connector
30
1
1 Angle bracket
25
1
Cutting angle bracket
to length
1 Angle bracket
2 Original vehicle stud bolt, plate nut
1
Mounting
angle
bracket
2
31
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 16
Ford Focus / C-Max / Grand C-Max
1
1 Cable tie, angle bracket
2 Cable tie
3 Passenger compartment wiring harnesses, heater control
4 Original vehicle wiring harness
2
4
Fastening
wiring harnesses
3
32
1
Position wiring harness of circulating pump 3
and route on the firewall to the centre.
1
1 Cable tie
2 Wiring harness of heater
Routing
wiring harnesses
3
2
33
All vehicles
1
Screw on M8 flanged nut 1 approx. 25mm on
original vehicle stud bolt.
Premounting flanged
nut
34
Screw on one M8 flanged nut 1 each approx.
25mm on original vehicle stud bolts.
1
1
Premounting flanged
nut
35
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 17
Ford Focus / C-Max / Grand C-Max
Preparing Heater
1
1 Water connection piece, sealing ring [2x
each]
2 5x15 self-tapping bolt, retaining plate of
water connection pieces
2
Mounting
water connection
pieces
36
1
1 Discard section
2 90° moulded hose
1
Cutting 90°
moulded
hose to
length
37
1
Mount combustion air pipe 2 on heater with
insulation strip 1 as installation aid.
1
3 Air-intake manifold
4 Fuel line
5 90° moulded hose, 10 mm dia. clamp [2x] Premounting heater
2
5
1
4
3
38
1 5x13 self-tapping bolt [3x]
2 50 mm edge protection [2x], divide at
centre
3 Bracket
1
3
Mounting
bracket
2
1
Ident. No.: 1316973E_EN
2
39
Status: 02.01.2013
© Webasto Thermo & Comfort SE 18
Ford Focus / C-Max / Grand C-Max
1
Fasten fuel line 2 on bracket with a half insulation strip 1 each.
1
Mounting
fuel line
40
2
115 kW Focus, C-Max and Grand C-Max
1 M6x16 bolt, spring lockwasher
2 Exhaust silencer
Mounting
exhaust silencer
2
41
1
1
Installing Heater
2
Install heater on firewall.
1 Wiring harness of heater [2x]
2 Circulating pump wiring harness
42
1
1
Attaching
wiring harnesses
1
Mount heater on original vehicle stud bolt [3x].
Pull fuel line 2 with wiring harness of metering
pump into 10 mm dia., 2100 mm long corrugated tube and route to the underbody along
original vehicle lines.
2
1 M8 flanged nut [2x]
Mounting
heater
43
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 19
Ford Focus / C-Max / Grand C-Max
1 M8 flanged nut
1
Mounting
heater
44
Align heater as shown. Ensure sufficient distance from neighbouring components, especially from A/C line 1. Correct if necessary.
1
Mounting
heater
45
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 20
Ford Focus / C-Max / Grand C-Max
Fuel
CAUTION!
Open the vehicle's fuel tank cap, ventilate the tank and then re-close the tank lock.
Any fuel running off should be collected in an appropriate container.
Install fuel line and metering pump wiring harness so that they are protected against stone impact. Unless specified otherwise, always fasten using cable ties.
Mount the fuel line and wiring harness with rub protection on sharp edges.
WARNING!
The fuel line and wiring harness are routed to the metering pump as shown in the wiring harness routing diagram.
1
2
3
Complete connector of metering pump after
routing. Pin assignment is not relevant.
4
5
1
2
3
4
5
Connector housing
Lock
Blue/brown (bl / br) wires
Coding
Timer lock
Dismantling connector
5
46
1 Fuel line and wiring harness of metering
pump in corrugated tube
1
Routing
lines
1
47
Remove fuel tank according to manufacturer's instructions. Remove and dismantle fueltank sending unit 1 according to manufacturer's instructions. Cut off 5mm from connection piece 2 and countersink gently.
1
Fuel extraction
2
48
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 21
Ford Focus / C-Max / Grand C-Max
1 Drill out 5.1 mm dia. hole
Fuel extraction
1
49
Cut standpipe 2 to length at centre in the
bulge as shown.
1
1 Cutting point
3 Discard section
Shortening
fuel standpipe
3
2
50
1 Connection pieces
Installing
fuel standpipe
1
51
Paste fuel standpipe 2 in the connection
piece 1 with suitable contact adhesive. Cut
standpipe 2 to length obliquely at the end
(measured from standpipe passage).
1
2
Installing
fuel standpipe
180
52
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 22
Ford Focus / C-Max / Grand C-Max
1 Installing retaining clamp
2 Standpipe
1
1
Fixing of
fuel
standpipe
2
53
2
Install fuel-tank sending unit 1 in accordance
with manufacturer's instructions. Mount coupling piece 2 on connection piece
1
2
Fuel extraction
54
Install fuel-tank according to manufacturer's
instructions.
1
1 Fuel line
2 Moulded hose
3 10mm dia. clamp
3
55
2
1
2
Focus / C-Max
3
1
2
3
4
5
6
7
7
6
Ident. No.: 1316973E_EN
5
Connecting fuel line
4
Perforated bracket
Cable tie
Metering pump
180° moulded hose, 10 mm dia. clamp
M6x25 bolt, flanged nut
Mounting of metering pump
90° moulded hose, 10 mm dia. clamp
Premounting metering pump
56
Status: 02.01.2013
© Webasto Thermo & Comfort SE 23
Ford Focus / C-Max / Grand C-Max
1 Perforated bracket
2 Original vehicle bolt
3 Fuel line of fuel standpipe in corrugated
tube
4 10 mm dia. clamp
4
Mounting
metering
pump
1
3
57
2
1
2
Check the position of the components; adjust
if necessary. Check that they have freedom of
movement.
3
1
2
3
4
Fuel line of heater
10 mm dia. clamp
Cable tie
Wiring harness of metering pump, connector mounted
Connecting metering pump
58
4
Grand C-Max
1
1 Perforated bracket
Angling
down perforated
bracket
57
90°
1
1
2
3
4
5
2
M6x25 bolt, washer, flanged nut
Cable tie
Mounting of metering pump
Metering pump
Perforated bracket
3
5
Ident. No.: 1316973E_EN
4
Premounting metering pump
59
Status: 02.01.2013
© Webasto Thermo & Comfort SE 24
Ford Focus / C-Max / Grand C-Max
Detach retaining clip of original vehicle wiring
harness 1 at position 2.
1
2 Drill out 9.1 mm dia. hole, rivet nut
Installing
rivet nut
60
2
1 M6x20 bolt, spring lockwasher
2 Perforated bracket
Mounting
metering
pump
2
61
1
1
2
1 180° moulded hose, 10 mm dia. clamp [2x]
2 Fuel line of fuel standpipe in corrugated
tube
3 Wiring harness of metering pump, connector mounted
4 Fuel line of heater
Connect5 Hose section, 10 mm dia. clamp [2x]
ing metering pump
3
5
1
4
62
Check the position of the components; adjust
if necessary. Check that they have freedom of
movement.
2
1 Fuel line of fuel standpipe in corrugated
tube
2 Cable tie
3 Adhesive base, cable tie
4 Fuel line of heater and wiring harness of
metering pump in corrugated tube
4
Ident. No.: 1316973E_EN
3
Routing
lines
63
Status: 02.01.2013
© Webasto Thermo & Comfort SE 25
Ford Focus / C-Max / Grand C-Max
1
2
Combustion Air
3
1
2
3
4
4
Ident. No.: 1316973E_EN
Silencer
51 mm dia. clamp
Combustion air pipe
Original vehicle stud bolt, washer, original vehicle nut (covered by clamp)
Mounting
silencer
64
Status: 02.01.2013
© Webasto Thermo & Comfort SE 26
Ford Focus / C-Max / Grand C-Max
1
Exhaust Gas
2
1 Exhaust pipe
a = 190
2 Exhaust end section
b = 350
a
Preparing
exhaust
pipe
b
1 Perforated bracket
1
Angling
down perforated
bracket
78
90°
1 Perforated bracket
2 M6x20 bolt, flanged nut, existing hole
1
Mounting
perforated
bracket
65
2
77kW Focus
1
1
2
3
4
4
3
Ident. No.: 1316973E_EN
2
Silencer
M6x16 bolt
M6x16 bolt, spring lockwasher
Perforated bracket
Premounting silencer
66
Status: 02.01.2013
© Webasto Thermo & Comfort SE 27
Ford Focus / C-Max / Grand C-Max
1 Flanged nut
2 Bracket
1
Mounting
silencer
67
2
1 Hose clamp [2x]
2 Exhaust pipe
1
Mounting
exhaust
pipe
2
68
1
1 Hose clamp
2 Exhaust end section
1
Mounting
exhaust
end section
2
69
92kW / 110kW Focus, C-Max and Grand
C-Max
1
1 Hose clamp [2x]
2 Exhaust pipe
Mounting
exhaust
pipe
2
Ident. No.: 1316973E_EN
1
70
Status: 02.01.2013
© Webasto Thermo & Comfort SE 28
Ford Focus / C-Max / Grand C-Max
1 Hose clamp
2 Exhaust end section
1
Mounting
exhaust
end section
2
71
All vehicles
1
2
1
2
3
4
Exhaust end section
M6x20 bolt, flanged nut
Perforated bracket
P-clamp
4
3
Fastening
exhaust
end section
72
1 Underride protection
2 60 mm dia. hole
1
Cutting out
underride
protection
170
105
73
2
Mount underride protection of engine 1. Align
exhaust end section 2 flush on underride protection 1. Ensure sufficient distance from
neighbouring components.
1
Aligning
exhaust
end section
2
Ident. No.: 1316973E_EN
74
Status: 02.01.2013
© Webasto Thermo & Comfort SE 29
Ford Focus / C-Max / Grand C-Max
Coolant Circuit
WARNING!
Any coolant running off should be collected in an appropriate container. Route hoses kink-free. Unless
specified otherwise, always fasten using cable ties. Position clamps so that other hoses cannot be
damaged. When installing the hoses, the heater must be filled with coolant.
The connection should be "inline" based on the following diagram:
Hose routing diagram
B
C
1
A
All spring clips
= 25 mm dia. Hose clamp
All connecting pipes
= 18x18 mm dia.
1 = Black (sw) rubber isolator
Ident. No.: 1316973E_EN
= 20-27 mm dia.
Status: 02.01.2013
© Webasto Thermo & Comfort SE 30
Ford Focus / C-Max / Grand C-Max
Discard section X.
Hose C = 180°, 18 mm dia. moulded hose.
A
B
A =
B =
X
260
225
Cutting
hoses to
length
C
1 100 mm long heat shrink plastic tubing
B
35
Preparing
hose B
75
1
Cut hose of engine outlet / heat exchanger inlet at the marking. Open lock of original vehicle hose bracket 3, will be relocked.
1
35
1 Hose on heat exchanger inlet
2 Hose of engine outlet
2
3
Cutting
point
76
1 Black (sw) rubber isolator
2 Hose on heat exchanger inlet
C
2
Ident. No.: 1316973E_EN
1
Connecting heat exchanger
inlet
77
Status: 02.01.2013
© Webasto Thermo & Comfort SE 31
Ford Focus / C-Max / Grand C-Max
B
Connection on
heater outlet
C
78
1
65
2
20
1 Perforated bracket
2 Discard section
Cutting to
length and
bending
perforated
bracket
26
46
45°
1
1
2
3
4
2
M6x25 bolt, flanged nut
Perforated bracket
Circulating pump
Circulating pump mounting
Premounting circulating
pump
4
79
3
1
1 Perforated bracket
2 Original vehicle stud bolt, with nut
3 Mount wiring harness of circulating pump
2
Mounting
circulating
pump
3
Ident. No.: 1316973E_EN
80
Status: 02.01.2013
© Webasto Thermo & Comfort SE 32
Ford Focus / C-Max / Grand C-Max
1 Hose of engine outlet
2 Hose bracket
3 Close lock of hose bracket
1
Connecting engine
outlet
2
81
3
Align hoses. Ensure sufficient distance from
neighbouring components.
Connection on
heater inlet
A
Ident. No.: 1316973E_EN
82
Status: 02.01.2013
© Webasto Thermo & Comfort SE 33
Ford Focus / C-Max / Grand C-Max
Final Work
WARNING!
Mount removed parts in reverse order. Check all hoses, clamps and all electrical connections for firm
seating. Insulate and tie back all loose wires.
Only use manufacturer-approved coolant. Spray heater components with anti-corrosion wax
(Tectyl 100K, Order No. 111329).
•
•
•
•
Connect the battery.
Fill and bleed the coolant circuit according to the vehicle manufacturer’s specifications.
Adjust digital timer, teach Telestart transmitter.
Make settings on A/C control panel according to the "Operating Instructions for End Customer".
• Place the "Switch off parking heater before refuelling" signboard in the area of the filler
neck.
• See installation instructions for initial startup and function check.
Webasto Thermo & Comfort SE
Postfach 1410
82199 Gilching
Germany
Internet: www.webasto.com
Technical Extranet:
http://dealers.webasto.com
Ident. No.: 1316973E_EN
Status: 02.01.2013
© Webasto Thermo & Comfort SE 34
Ford Focus / C-Max / Grand C-Max
Operating Instructions for Manual A/C Focus
Please remove this page in case of manual air-conditioning and add it to the vehicle operating instructions.
Note:
We recommend matching the heating time to the driving time.
Heating time = driving time
Example:
For a driving time of approx. 20 min. (in one direction), we recommend not exceeding a switch-on time
of 20 min.
Passenger compartment monitoring , if installed, must be deactivated in addition to the vehicle settings
for the heating operation.
Instructions for deactivation can be taken from the operating instructions manual of the vehicle.
Before parking the vehicle, make the following settings:
1
2
1 Set fan to level "1", or max. "2"
2 Air outlet to windscreen
3 Set temperature to "max."
A/C control
panel
83
3
1 30A main fuse F2 of passenger compartment
2 20A fuse F1 of heater
1
Fuses of
engine
compartment
2
84
1 1A fuse F3 of heater control
2 25A fan fuse F4
Fuses of
passenger
compartment
2
1
85
Ford Focus / C-Max / Grand C-Max
Operating Instructions for Automatic A/C Focus
Please remove this page in case of automatic air-conditioning and add it to the vehicle operating instructions.
Note:
We recommend matching the heating time to the driving time.
Heating time = driving time
Example:
For a driving time of approx. 20 min. (in one direction), we recommend not exceeding a switch-on time
of 20 min.
Passenger compartment monitoring , if installed, must be deactivated in addition to the vehicle settings
for the heating operation.
Instructions for deactivation can be taken from the operating instructions manual of the vehicle.
Before parking the vehicle, make the following settings:
1
Fan speed need not be pre-set.
1
1 Set temperature to "HI"
2 Air outlet to windscreen
A/C control
panel
2
86
1 30A main fuse F2 of passenger compartment
2 20A fuse F1 of heater
1
Fuses of
engine
compartment
2
87
1 1A fuse F3 of heater control
2 25A fan fuse F4
Fuses of
passenger
compartment
2
1
88
Ford Focus / C-Max / Grand C-Max
Operating Instructions for Automatic A/C C-Max / Grand C-Max
Please remove this page in case of automatic air-conditioning and add it to the vehicle operating instructions.
Note:
We recommend matching the heating time to the driving time.
Heating time = driving time
Example:
For a driving time of approx. 20 min. (in one direction), we recommend not exceeding a switch-on time
of 20 min.
Passenger compartment monitoring , if installed, must be deactivated in addition to the vehicle settings
for the heating operation.
Instructions for deactivation can be taken from the operating instructions manual of the vehicle.
Before parking the vehicle, make the following settings:
1
Fan speed need not be pre-set.
1
1 Set temperature to "HI"
2 Air outlet to windscreen
A/C control
panel
2
89
1 30A main fuse F2 of passenger compartment
2 20A fuse F1 of heater
1
Fuses of
engine
compartment
2
90
1 1A fuse F3 of heater control
2 25A fan fuse F4
Fuses of
passenger
compartment
2
1