1955-56 CHEVY
GEN IV
56155-PCZ
18865 GOLL ST. - SAN ANTONIO, TX. - 78266 ph.210-654-7171 - fax 210-654-3113
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 1 OF 24
GEN IV 1955-56 CHEVY
Table of Contents
PAGES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
COVER
TABLE OF CONTENTS
PACKING LIST
INFORMATION PAGE
WIRING NOTICE
ENGINE & PASSENGER COMPARTMENT FIGURES 1& 2
CONDENSER ASSEMBLY
- CORE SUPPORT FIGURES 3-3b
COMPRESSOR BRACKET
- PULLEYS - FIGURE 4
DEFROST DUCT INSTALLATION - FIGURE 5
CONTROL PANEL CONVERSION
EVAPORATOR INSTALLATION, FIGURES 6 & 6a
EVAPORATOR INSTALLATION CONT., FIGURE 6b & FIGURE 7
PASSENGER & DRIVER SIDE UNDER DASH LOUVER INSTALLATION FIGURE 8
- DRAIN HOSE INSTALLATION FIGURE 9
O-RING LUBRICATING/FITTING TIGHTENING, FIGURES 10 & 11
-HEATER CONTROL VALVE INSTALLATION FIGURE 12
HARDLINE, A/C HOSE, & HEATER CONTROL VALVE INSTALLATION
A/C HOSE ROUTING, FIGURES 13-13b
FIREWALL COVER INSTALLATION FIGURE 14
FINAL STEPS DUCT HOSE ROUTING & CONTROL HARNESS INSTALLATION
FIGURE 15
GLOVE BOX INSTALLATION FIGURE 16
EVAPORATOR HARDLINE INSTALLATION FIGURE 17
WIRING DIAGRAM
OPERATION OF CONTROLS
TROUBLE SHOOTING
THERMOSTAT ADJUSTMENT
CORE SUPPORT TEMPLATE
EVAPORATOR KIT PACKING LIST
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 2 OF 24
2
GEN IV 1955-56 CHEVY
EVAPORATOR KIT PACKING LIST
No.
1.
2.
QTY.
1
1
PART No.
760155-VCE
78255-PCN
EVAPORATOR KIT
56155-PCZ
DESCRIPTION
1955-56 CHEV. EVAP. SUBCASE
1955-56 CHEV. CAR WO AC ACC. KIT
** BEFORE BEGINNING INSTALLATION OPEN ALL PACKAGES AND CHECK CONTENTS OF SHIPMENT.
PLEASE REPORT ANY SHORTAGES DIRECTLY TO VINTAGE AIR WITHIN 15 DAYS. AFTER 15 DAYS,
VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS.
1
1955-56 CHEVY EVAP.
SUB CASE 760155-VCE
2
DASH
C
O
L
D
3
ACCESSORY KIT
78255-PCN
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 3 OF 24
FLOO
R
DEF
H
E
A
T
GEN IV 1955-56 CHEVY
1955-56 CHEVROLET
GEN IV
IMPORTANT NOTICE-PLEASE READ
FOR MAXIMUM SYSTEM PERFORMANCE
VINTAGE AIR RECOMMENDS THE FOLLOWING:
*18” HEAVY DUTY FAN - 32918-VUF
*1955-57 CHEVY FAN SHROUD (V/8 RADIATOR POSITION)- 37155-VCF, OR
1955-57 CHEVY FAN SHROUD (6 cyl. RADIATOR POSITION)-32057-VCF
*16” SPAL AUXILIARY CONDENSER FAN PACKAGE - 32007-VUF
THIS KIT DOES NOT CONTAIN HEATER HOSE. YOU MUST PURCHASE 8 FEET OF 5/8” DIA.
HEATER HOSE FROM VINTAGE AIR(31800-VUD) OR FROM YOU LOCAL PARTS RETAILER
SAFETY SWITCHES:
YOUR VINTAGE AIR SYSTEM IS EQUIPPED WITH A BINARY PRESSURE SAFETY
SWITCH. A BINARY SWITCH (11078-VUS) DISENGAGES THE COMPRESSOR
CLUTCH IN CASE OF EXTREME LOW PRESSURE CONDITION (REFRIGERANT LOSS)
OR EXCESSIVELY HIGH HEAD PRESSURE (406 lb.), TO PREVENT COMPRESSOR
DAMAGE OR HOSE RUPTURE. A TRINARY SWITCH (11076-VUS) COMBINES
HI/LO PRESSURE PROTECTION WITH AN ELECTRIC FAN OPERATION SIGNAL AT
254 lbs., AND MAY BE SUBSTITUTED FOR USE WITH ELECTRIC CONDENSER FANS.
COMPRESSOR SAFETY SWITCHES ARE EXTREMELY IMPORTANT SINCE AN A/C SYSTEM
RELIES ON REFRIGERANT TO CARRY LUBRICATION THROUGH THE SYSTEM.
SERVICE INFO:
EVACUATE THE SYSTEM FOR 35-45 MINUTES WITH SYSTEM COMPONENTS
(DRIER, COMPRESSOR, EVAPORATOR AND CONDENSER) AT A TEMPERATURE
OF AT LEAST 85° F. ON A COOL DAY THE COMPONENTS CAN BE HEATED
WITH A HEAT GUN OR BY RUNNING THE ENGINE WITH THE HEATER ON
BEFORE EVACUATING. LEAK CHECK AND CHARGE TO SPECIFICATIONS.
THE PROPER AMOUNT OF REFRIGERANT IS CRITICAL TO PROPER SYSTEM
OPERATION. VINTAGE AIR RECOMMENDS OUR SYSTEMS BE CHARGED BY
WEIGHT WITH A QUALITY CHARGING STATION OR SCALE.
REFRIGERANT CAPACITIES
134a SYSTEM
CHARGE WITH 1.8 lbs. (1lbs. 12ozs) OF REFRIGERANT
R-12 SYSTEM
CHARGE WITH 2.0 lbs. OF REFRIGERANT
LUBRICANT CAPACITIES
NEW COMPRESSOR - NO ADDITIONAL OIL NEEDED
USED COMPRESSOR - CONSULT VINTAGE AIR
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 4 OF 24
4
GEN IV 1955-56 CHEVY
IMPORTANT WIRING NOTICE-PLEASE READ
SOME VEHICLES MAY HAVE HAD SOME OR ALL OF THEIR RADIO INTERFERENCE CAPACITORS
REMOVED. THERE SHOULD BE A CAPACITOR FOUND AT EACH OF THE FOLLOWING LOCATIONS:
1. ON THE POSITIVE TERMINAL OF THE IGNITION COIL
2. IF THERE IS A GENERATOR, ON THE ARMATURE TERMINAL OF THE GENERATOR
3. IF THERE IS A GENERATOR, ON THE BATTERY TERMINAL OF THE VOLTAGE REGULATOR
MOST ALTERNATORS HAVE A CAPACITOR INSTALLED INTERNALLY TO ELIMINATE WHAT IS CALLED
'WHINING' AS THE ENGINE IS REVVED. IF WHINING IS HEARD IN THE RADIO, OR JUST TO BE EXTRA
CAUTIOUS, A RADIO INTERFERENCE CAPACITOR CAN BE ADDED TO THE BATTERY TERMINAL OF
THE ALTERNATOR.
IT IS ALSO IMPORTANT THAT THE BATTERY LEAD IS IN GOOD SHAPE AND THAT THE GROUND
LEADS ARE NOT COMPROMISED. THERE SHOULD BE A HEAVY GROUND FROM THE BATTERY TO
THE ENGINE BLOCK, AND ADDITIONAL GROUNDS TO THE BODY AND TO THE CHASSIS.
IF THESE PRECAUTIONS ARE NOT OBSERVED, IT IS POSSIBLE FOR VOLTAGE SPIKES TO BE PRESENT
ON THE BATTERY LEADS. THESE SPIKES COME FROM IGNITION SYSTEMS, CHARGING SYSTEMS,
AND FROM TURNING SOME OF THE VEHICLE'S OTHER SYSTEMS ON AND OFF. MODERN
COMPUTER OPERATED EQUIPMENT CAN BE SENSITIVE TO VOLTAGE SPIKES ON THEIR POWER
LEADS, WHICH CAN CAUSE UNEXPECTED RESETS, STRANGE BEHAVIOR, AND MAY ALSO CAUSE
PERMANENT DAMAGE.
VINTAGE AIR STRIVES TO HARDEN THEIR PRODUCTS AGAINST THESE TYPES OF ELECTRICAL NOISE,
BUT THERE IS A POINT WHERE A VEHICLE'S ELECTRICAL SYSTEM CAN BE DEGRADED SO MUCH
THAT NOTHING CAN HELP.
RADIO INTERFERENCE CAPACITORS SHOULD BE AVAILABLE AT MOST AUTO & TRUCK PARTS
SUPPLIERS. THEY TYPICALLY ARE CYLINDRICAL IN SHAPE, A LITTLE OVER AN INCH LONG, A LITTLE
OVER A HALF INCH IN DIAMETER, THEY HAVE A SINGLE LEAD COMING FROM ONE END OF THE
CYLINDER WITH A TERMINAL ON THE END OF THE WIRE, AND THEY WILL HAVE A MOUNTING CLIP
WHICH IS SCREWED INTO A GOOD GROUND ON THE VEHICLE. THE SPECIFIC VALUE OF THE
CAPACITANCE IS NOT TOO SIGNIFICANT, IN COMPARISON TO IGNITION CAPACITORS THAT ARE
MATCHED WITH THE COIL TO REDUCE PITTING.
CARE MUST BE TAKEN WHEN INSTALLING THE COMPRESSOR LEAD, NOT TO SHORT
IT TO GROUND. THE COMPRESSOR LEAD MUST NOT BE CONNECTED TO A CONDENSER
FAN OR ANY OTHER AUXILIARY DEVICE. SHORTING TO GROUND OR CONNECTING
TO A CONDENSER FAN OR ANY OTHER AUXILIARY DEVICE WILL CAUSE SEVERE DAMAGE
TO THE ECU.
WHEN INSTALLING GROUND LEADS ON GEN IV SYSTEMS, THE BLOWER CONTROL GROUND
AND ECU GROUND MUST BE CONNECTED DIREECTLY TO THE NEGATIVE BATTERY POST.
THE HEATER CONTROL VALVE IS A NORMALLY OPEN VALVE. IT MUST BE CONNECTED TO
THE ECU TO BLOCK WATER FLOW IN AC MODE.
5
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 5 OF 24
GEN IV 1955-56 CHEVY
INSTALLATION INSTRUCTIONS FOR
1955-1956 CHEVROLET
BEFORE STARTING THE AIR CONDITIONER INSTALLATION, CHECK FOR PROPER OPERATION OF ALL COMPONENTS (RADIO,
LIGHTS, WIPERS, ETC.). STUDY THE INSTRUCTIONS, ILLUSTRATIONS AND DIAGRAMS. FOR EASE OF INSTALLATION
CHECK OFF ( ) EACH PROCEDURE PRIOR TO MOVING ON TO THE NEXT STEP.
ENGINE COMPARTMENT
DISCONNECT BATTERY AND REMOVE
REMOVE BATTERY TRAY
REMOVE AIR CLEANER
DRAIN RADIATOR
DISCONNECT HEATER HOSES
PASSENGER COMPARTMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
REMOVE OEM HEATER ASSEMBLY, INCLUDES: CONTROL CABLES, TWO (2) 7/16" NUTS ON FIREWALL AND ONE (1)
UNDER DASH (DISCARD).
REMOVE HEATER BLOWER (DISCARD). SEE FIGURE 1 BELOW.
REMOVE DUCT ABOVE KICK PANEL VENT WITH BUTTERFLY AND PANEL FLANGE (DISCARD). INSTALL NEW VENT
COVER AS FIGURE 2 SHOWS.
REMOVE GLOVE BOX DOOR (RETAIN).
REMOVE GLOVE BOX (DISCARD).
REMOVE THE ORIGINAL DEFROSTER DUCT FROM HEATER TO WINDSHIELD (DISCARD).
REMOVE ASH TRAY (RETAIN).
REMOVE ASH TRAY SLIDER ASSEMBLY (RETAIN).
REMOVE VENT & CABLE FROM DASH (RETAIN. SEE FIGURE 1 BELOW.
REMOVE CONTROL PANEL (RETAIN), REFER TO CONTROL PANEL CONVERSION KIT TO ASSEMBLE CONTROL
PANEL.
REMOVE PASSENGER SIDE SPEAKER GRILLE (RETAIN). SEE FIGURE 1 BELOW.
OEM
SCREWS
6
11
FIGURE 2
5
9
2
8
7
10
4
FIGURE 1
1
3
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 6 OF 24
6
GEN IV 1955-56 CHEVY
CONDENSER ASSEMBLY
LOOSEN THE SIX BOLTS THAT SECURE THE RADIATOR TO THE CORE SUPPORT.
SLIDE THE CONDENSER ASSEMBLY INTO POSITION. THE CONDENSER BRACKETS WILL BE HELD BETWEEN
THE RADIATOR AND CORE SUPPORT, SECURED WITH THE SIX RADIATOR BOLTS. SEE FIGURE 3 & 3b BELOW.
HOLDING THE CONDENSER IN POSITION, TIGHTEN THE SIX RADIATOR BOLTS.
CORE SUPPORT
LOCATE THE TEMPLATE ON PAGE 23, AND ALIGN THIS TEMPLATE ON THE PASSENGER SIDE CORE SUPPORT
PANEL. USING THE TEMPLATE, MARK HOLES AND CUT THE 1 1/4” HOLE, USING A HOLE SAW. DRILL THE
5/16” HOLE IN NOTED LOCATION. SEE FIGURE 3a BELOW.
INSTALL THE #6 AND #8 CONDENSER LINES THROUGH 1 1/4” HOLE . LUBRICATE O-RINGS ( SEE FIGURES 10 & 11,
PAGE 12) AND CONNECT LINES TO CONDENSER
O.E.M.
LOCATE THE SPLIT GROMMET AND INSTALL AS SHOWN IN FIGURE 3b, BELOW.
RADIATOR
INSTALL DRIER LOOSELY AS SHOWN IN FIGURE 3b BELOW.
NOTE: REFRIGERANT FLOW. (ARROW ON DRIER)
FIGURE 3a
HOLE IN
CORE SUPPORT
1/4” NUT
(18136-VUB)
w/ FLAT WASHER
(18125-VUB)
CORE SUPPORT
TEMPLATE
1-1/4”
5/16”
SIDE OF CORE
SUPPORT
VINTAGE AIR
CONDENSER
NOTE: #8 (LARGER)
FITTING AT TOP OF
RADIATOR
FLOW
#8 COND. LINE
35018-VCG
DRIER
INSTALL 8 #6 x 3/8”
PANHEAD SCREWS
5/16”
BOLTS
1/4” x 1” BOLT
(18290-VUB)
#6 COND. LINE
35017-VCG
SPLIT
GROMMET
FIGURE 3b
INSTALLATION OF CONDENSER HARDLINES
MOUNT DRIER
TO INSIDE OF
CORE SUPPORT
THRU 5/16” HOLE
#8
..
..
..
..
#6
7
FIGURE 3
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 7 OF 24
GEN IV 1955-56 CHEVY
COMPRESSOR & BRACKETS
REFER TO SEPARATE INSTRUCTIONS INCLUDED WITH THE BRACKET KIT TO INSTALL THE
COMPRESSOR BRACKET. REFER TO FIGURE 4 BELOW FOR COMPRESSOR MOUNTING POSITION.
PULLEYS
IN MOST INSTANCES EXISTING BELT LENGTHS WILL REMAIN THE SAME. SEE FIGURE 4 BELOW.
TAB
"E"
PULLEYS (VINTAGE AIR) SHORT PUMP
SMALL BLOCK CHEVY (STEEL PULLEY)
TAB
"A"
22503-VCA - WATER PUMP PULLEY
(DOUBLE GROOVE)
GENERATOR
OR
ALTERNATOR
COMPRESSOR
22506-VCA - CRANKSHAFT PULLEY
(DOUBLE GROOVE)
TAB
"G"
(WITH POWER STEERING
A 3 GROOVE CRANK
PULLEY IS REQUIRED)
22507-VCA - CRANKSHAFT PULLEY
(TRIPLE GROOVE)
NOTE: BELT ROUTING MAY VARY
WITH DIFFERENT BRACKET SETS.
ALWAYS REFER TO INSTRUCTIONS
INCLUDED WITH BRACKETS.
MOUNT THE
COMPRESSOR
USING TABS
"G" & "C"
TAB
"C"
WATER PUMP
PULLEY
CRANKSHAFT
PULLEY
FIGURE 4
DEFROST DUCT INSTALLATION
INSTALL DEFROST DUCTS WITH 2” DUCT HOSE (PASSENGER SIDE) 2” x 10” (DRIVER SIDE) 2” x 24”
SEE FIGURE 5 BELOW & FIGURE 15, PAGE 16
INSTALL THE DEFROSTER DUCTS AT THIS TIME. SEE FIGURE 5 & 5a.
NOTE: ROUNDED SIDE OF DUCTS FACE PASSENGER AREA.
#8 x ½" PH PAN
HEAD SCREW
FOR 1955 MODEL
USING EXISTING
HOLES
FIGURE 5
#8 x ½" PH PAN
HEAD SCREW
FOR 1956 MODEL
USING EXISTING
HOLES
DEFROST HOLE
SEAT THE BRACKET
IN DEFROSTER HOLE
DEFROST DUCT
(ROUNDED SIDE OUT)
FIGURE 5a
CONTROL PANEL CONVERSION
LOCATE THE CONTROL PANEL CONVERSION KIT (473055-PCA), REFER TO INSTRUCTIONS SUPPLIED WITH
CONVERSION KIT TO ASSEMBLE CONTROL PANEL.
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 8 OF 24
8
GEN IV 1955-56 CHEVY
EVAPORATOR INSTALLATION
ON A WORK BENCH, INSTALL EVAPORATOR REAR BRACKETS, AND INSTALL EVAPORATOR HARDLINES WITH
PROPERLY LUBRICATED O-RINGS. (SEE FIGURE 17, PAGE 18, AND FIGURES 10, 11 & 12, PAGE 12.)
LIFT EVAPORATOR UNIT UP & UNDER THE DASHBOARD (SEE FIGURES 6-6a BELOW & FIGURE 6b, PAGE 10). SECURE
LOOSELY TO THE FIREWALL FROM THE ENGINE COMPARTMENT SIDE WITH (2) 1/4-20 x 1” BOLTS AND WASHERS.
SEE FIGURE 7, PAGE 10 & FIGURE 17, PAGE 18.
INSTALL FRONT MOUNTING BRACKET TO EVAPORATOR UNIT WITH 1/4-20 x 1/2” BUTTON HEAD BOLT AND TIGHTEN AS
SHOWN IN FIGURE 7, PAGE 10. LOOSELY ATTACH FRONT MOUNTING BRACKET TO DASH WITH 1/4-20 x 1” BOLT,
WASHER AND NUT. SEE FIGURE 7, PAGE 10
INSTALL CENTER A/C PLENUM TO EVAPORATOR WITH (2) 10/32 x 1/2” SCREWS. SEE FIGURE 7, PAGE 10.
LOOSELY SECURE THE CENTER PLENUM TO DASH WITH THE CENTER PLENUM MOUNTING BRACKET, USING
A 1/4-20 x 1” BOLT AND WASHER. SEE FIGURE 7, PAGE 10
VERIFY THAT EVAPORATOR UNIT IS LEVEL AND SQUARE TO THE DASH, THEN TIGHTEN ALL MOUNTING BOLTS.
(NOTE: TIGHTEN THE TWO BOLTS ON FIREWALL FIRST, THEN THE FRONT MOUNTING BRACKET BOLT AND
NUT. TIGHTEN THE CENTER PLENUM MOUNTING BOLT LAST).
FIGURE 6
INSTALL EVAPORATOR UNIT FROM
PASSENGER SIDE FLOOR BOARD.
FIGURE 6a
9
ROTATE EVAPORATOR UNIT SO LINES PASS THROUGH
OPENING IN FIREWALL AND LIFT INTO PLACE.
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 9 OF 24
GEN IV 1955-56 CHEVY
ONCE INTO PLACE SECURE EVAPORATOR
UNIT TO FIREWALL.
FIGURE 6b
1/4-20 x 1”
BOLT & WASHER
FIREWALL
ECU
MODULE
A/C-HEAT
BLEND
DOOR
DEFROST
DOOR
1/4-20
NUT
FRONT
MOUNTING
BRACKET
TO EVAP.
DASH/FLOOR
DOOR
TO
DASH
1/4-20 x 1/2”
BUTTON HEAD
SCREW
1/4-20 x 1”
1/4-20 x 1”
BOLT & WASHER
BOTTOM LIP OF DASH
WASHER
CENTER PLENUM
MOUNTING BRACKET
FIGURE 7
CENTER
A/C PLENUM
CENTER
A/C PLENUM
DASH
SIDE VIEW
10/32 x 1/2”
SCREW
10/32 x 1/2”
SCREW”
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 10 OF 24
10
GEN IV 1955-56 CHEVY
PASSENGER AND DRIVER SIDE UNDER DASH LOUVER INSTALLATION
FIGURE 8
INSTALL PASSENGER AND DRIVER SIDE BALL LOUVERS BY SLIDING THE SIDE FLANGE OF BALL LOUVER
BETWEEN THE KICK PANEL AND KICK PANEL RETAINING STRIP.
SLIDE LOUVER UP TOWARDS BOTTOM OF DASH UNTIL THE LOUVER IS SEATED AGAINST DASH, AND
SECURE TO KICK PANEL WITH SUPPLIED #8 x 1/2” PANHEAD SCREW. SEE FIGURE 8 ABOVE.
DRAIN HOSE INSTALLATION
IN-LINE WITH THE DRAIN, LIGHTLY MAKE A
MARK ON THE FIREWALL. MEASURE ONE INCH
DOWN AND DRILL A 5/8” HOLE THROUGH
THE FIREWALL. SEE FIGURE 9.
FIGURE 14 ON PAGE 15 WILL SHOW YOU ROUGHLY
THE HOLE LOCATION.
1”
DRAIN
HOSE
11
FIGURE 9
DRAIN
INSTALL DRAIN HOSE TO BOTTOM OF EVAPORATOR
UNIT AND ROUTE THROUGH FIREWALL. SEE FIGURE
9 AND FIGURE 14, PAGE 15.
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 11 OF 24
GEN IV 1955-56 CHEVY
TWIST WITH
THIS
WRENCH
HOLD WITH
THIS WRENCH
FIGURE 8
LUBRICATE
O'RING
(SEE FIGURE 11)
#8 O'RING
#6 O'RING
FIGURE 10
FOR A PROPER SEAL
OF FITTINGS INSTALL SUPPLIED
O'RINGS AS SHOWN
AND LUBRICATE WITH
SUPPLIED OIL.
O'RING
MALE
INSERT
#10 O'RING
FEMALE
NUT
SUPPLIED OIL
FOR O'RINGS
O'RING,
SLIDE OVER
MALE INSERT TO
SWAGED LIP
FIGURE 11
HEATER CONTROL
VALVE INSTALLATION
ECU
MODULE
FLO
W
#10 SUCTION
HOSE
TO
WA
TER
HEATER
HOSE
FIGURE 12
PUM
#6 LIQUID
LINE
P
FR
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 12 OF 24
OM
IN
TA
K
E
12
GEN IV 1955-56 CHEVY
HARDLINE & HOSE INSTALLATION
STANDARD HOSE KIT
LOCATE THE TWO COMPRESSOR ALUMINUM HARDLINE EXTENSIONS. SEE FIGURE 13, PAGE 14.
LOCATE THE #8 COMPRESSOR ALUMINUM HARDLINE. LUBRICATE (1) #8 O-RING AND INSTALL ON THE FEMALE
O-RING END. CONNECT THIS LINE TO THE #8 DISCHARGE PORT ON THE COMPRESSOR, AND TIGHTEN.
SEE FIGURES 10 & 11, PAGE 12.
LOCATE THE #10 COMPRESSOR ALUMINUM HARDLINE. LUBRICATE (1) #10 O-RING AND INSTALL ON THE FEMALE
O-RING END. CONNECT THIS LINE TO THE #10 SUCTION PORT ON THE COMPRESSOR, AND TIGHTEN. SEE
FIGURE 13, PAGE 14.
SECURE THE TWO COMPRESSOR HARDLINES TO THE COMPRESSOR, USING THE SUPPLIED CLAMP. SEE
FIGURE 13a, PAGE 14.
LOCATE THE #8 RUBBER HOSE. THIS HOSE WILL CONNECT TO THE #8 ALUMINUM COMPRESSOR
HARDLINE AND #8 ALUMINUM HARDLINE FROM CONDENSER. LUBRICATE (2) #8 O-RINGS, AND INSTALL
ONE ON EACH END OF THE #8 RUBBER HOSE. ROUTE HOSE AS SHOWN IN FIGURE 13, PAGE 14
AND TIGHTEN. NOTE: THE 90° DEGREE HOSE END CONNECTS TO THE CONDENSER HARDLINE .
INSTALL FIREWALL COVER. SEE FIGURE 14, PAGE 15.
INSTALL THE #6 LIQUID LINE, LUBRICATE (1) #6 O-RING AND TIGHTEN. SEE FIGURE 13b, PAGE 14.
LOCATE THE #10 RUBBER HOSE. THIS HOSE WILL CONNECT TO THE #10 ALUMINUM COMPRESSOR
HARDLINE AND #10 ALUMINUM HARDLINE FROM EVAPORATOR. LUBRICATE (2) #10 O-RINGS, AND INSTALL
ONE ON EACH END OF THE #10 RUBBER HOSE. ROUTE HOSE AS SHOWN IN FIGURE 13, PAGE 14
AND TIGHTEN. NOTE: THE 90° DEGREE HOSE END CONNECTS TO THE COMPRESSOR HARDLINE.
INSTALL HEATER HOSES TO HEATER LINES AND ROUTE AS SHOWN IN FIGURE 13-13b, PAGE 14. SECURE WITH
HOSE CLAMPS. NOTE: THIS KIT DOES NOT CONTAIN HEATER HOSE. YOU MUST PURCHASE
5/8” DIA. HEATER HOSE FROM YOUR LOCAL PARTS RETAILER.
MODIFIED HOSE KIT
REFER TO SEPARATE INSTRUCTIONS INCLUDED WITH MODIFIED HOSE KIT.
HEATER CONTROL VALVE & #6 LIQUID LINE
INSTALL HEATER CONTROL VALVE IN-LINE WITH INTAKE MANIFOLD (PRESSURE SIDE) HEATER HOSE.
SEE FIGURE 12, PAGE 12.
INSTALL THE #6 LIQUID LINE TO DRIER WITH LUBRICATED O-RING AND TIGHTEN. FIGURE 13, PAGE 14
INSTALL BINARY SWITCH ON #6 LIQUID LINE. SEE FIGURE 13, PAGE 14.
SECURE THE #6 LIQUID LINE TO THE FENDER USING THE SUPPLIED ADEL CLAMP. SEE FIGURE 13, PAGE 14.
13
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 13 OF 24
GEN IV 1955-56 CHEVY
AC/HEAT HOSE
& LINE ROUTING
ECU
MODULE
EVAPORATOR
SUB CASE
PRESS
TAPE
NOTE: COMPRESSOR HARDLINES
ARE INCLUDED WITH STANDARD
HOSE KIT ONLY.
HEATER
HOSES
HEATER
CONTROL
VALVE
#10 COMPRESSOR
ALUMINUM
HARDLINE EXT.
(SUCTION SIDE)
35037-VUG-A
EXPANSION
VALVE
FIREWALL
COVER
BINARY SWITCH
INSTALLATION
BINARY
SWITCH
#10 RUBBER
SUCTION HOSE
ADEL
CLAMP
#6 LIQUID LINE
#8 COMPRESSOR
ALUMINUM HARDLINE
EXT. (DISCHARGE SIDE)
35038-VUG-A
#8 RUBBER
HOSE
FIGURE 13
#6 LIQUID LINE FROM
EXPANSION VALVE
TO DRIER
(09154-PFL)
#8 COND. LINE
35018-VCG
#6 HARDLINE
35017-VCG
SPLIT RUBBER
GROMMET IN HOLE
IN CORE SUPPORT
NOTE: MODIFIED HOSE KITS INCLUDE
2 - 135° COMPRESSOR FITTINGS.
(REFER TO MODIFIED HOSE KIT INSTRUCTIONS
INCLUDED WITH HOSE KIT.)
FIGURE 13a
ALUMINUM
CLAMP
(STANDARD
HOSE KIT
ONLY)
ECU
MODULE
#10 SUCTION
LINE (INSULATED)
S
B
Y
FIREWALL
COVER
O-RING
#10 SUCTION
HOSE
FIGURE 13b
HEATER
HOSE
#6 LIQUID
LINE
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 14 OF 24
14
GEN IV 1955-56 CHEVY
FIREWALL COVER
PASS LINES THROUGH FIREWALL COVER, AND SECURE WITH (2) 1/4-20 BOLTS. SEE FIGURE 14 BELOW.
PASS. SIDE EVAP.
MOUNTING HOLE
DRIVER SIDE
EVAP. BRKT.
MOUNTING HOLE
1/4-20 x 1”
BOLT & WASHER
S B
Y
S B
Y
1/4-20
NUT
S B
Y
1/4-20 x 1”
BOLT & WASHER
1/4-20 x 1”
BOLT
S B
Y
DRAIN
HOLE
FIGURE 14
15
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 15 OF 24
GEN IV 1955-56 CHEVY
FINAL STEPS - DUCT HOSE ROUTING & CONTROL PANEL HARNESS
INSTALL DUCT HOSES AS SHOWN IN FIGURE 15 BELOW.
REMOVE THE CONTROL PANEL KNOBS AND BEZEL.
FROM THE BACK SIDE OF THE DASH, INSTALL THE CONTROL PANEL ASSEMBLY THROUGH THE CONTROL PANEL
OPENING IN DASH AS SHOWN IN FIGURE 15 BELOW.
REINSTALL BEZEL AND CONTROL KNOBS.
PLUG THE CONTROL PANEL HARNESS INTO THE ECU MODULE ON SUB CASE AS SHOWN. SEE FIGURE 15 BELOW.
CONNECT THE CONTROL HARNESS TO THE CONTROL POTS AS SHOWN BELOW.
PLUG THE WIRING HARNESS INTO THE ECU MODULE ON SUB CASE AS SHOWN. (WIRE ACCORDING TO WIRING
DIAGRAM ON PAGE 19.)
DASH
BEZEL
WHT
WHT/BLU
RED
CONTROL PANEL
DASH OPENING
BACKING
PLATE
DAS
H
C
O
L
D
FLO
WHT
WHT/RED
RED
WHT
WHT WHT/GRN
WHT/YEL
RED
RED
OR
ECU
MODULE
DEF
H
E
A
T
NEW
PLACARD
PLUG
FROM
WIRING
HARNESS
PASSENGER
SIDE LOUVER
2 1/2” x 42”
PASSENGER SIDE
DEF. DUCT
2” x 10”
DRIVER SIDE
LOUVER
2 1/2” x 48”
DRIVER SIDE
DEF. DUCT
2” x 24”
FIGURE 15
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 17 OF 24
16
GEN IV 1955-56 CHEVY
INSTALL GLOVE BOX BOTTOM AND GLOVE BOX DOOR, SECURE TO DASH WITH (3) O.E.M. SCREWS.
SEE FIGURE 16, BELOW.
WITH GLOVE BOX BOTTOM AND DOOR IN PLACE, INSTALL GLOVE BOX TOP AS SHOWN, SECURE THE GLOVE BOX
TOP AND BOTTOM TOGETHER USING (3) 6 x 3/8” PAN HEAD SCREWS AS SHOWN.
SECURE THE GLOVE BOX TOP TO DASH USING (2) OEM SCREWS, SEE FIGURE 16 BELOW.
(3) O.E.M. SCREW
GLOVE
BOX DOOR
DASH
PLASTIC GLOVE
BOX BOTTOM
GLOVE
BOX HINGE
(2) O.E.M. SCREW
FIGURE 16
GLOVE
BOX TOP
REINSTALL ALL PREVIOUSLY REMOVED ITEMS (BATTERY BOX & BATTERY).
(3) 6 x 3/8”
PAN HEAD
SCREW
FILL RADIATOR WITH AT LEAST A 50/50 MIXTURE OF APPROVED ANTIFREEZE AND WATER.
IT IS THE OWNER'S RESPONSIBILITY TO KEEP THE FREEZE PROTECTION AT THE PROPER LEVEL
FOR THE CLIMATE IN WHICH THE VEHICLE IS OPERATED. FAILURE TO FOLLOW ANTIFREEZE
RECOMMENDATIONS WILL CAUSE HEATER CORE TO CORRODE PREMATURELY AND POSSIBLY
BURST IN AC MODE AND/OR FREEZING WEATHER, VOIDING YOUR WARRANTY.
DOUBLE CHECK ALL FITTINGS, BRACKETS AND BELTS FOR TIGHTNESS.
VINTAGE AIR RECOMMENDS THAT ALL AC SYSTEMS BE SERVICED BY A CERTIFIED AUTOMOTIVE AIR
CONDITIONING TECHNICIAN.
EVACUATE THE SYSTEM FOR A MINIMUM OF 45 MINUTES PRIOR TO CHARGING AND LEAK CHECK
PRIOR TO SERVICING.
17
CHARGE THE SYSTEM TO THE CAPACITIES STATED ON THE INFORMATION PAGE (PAGE 4) OF THIS
INSTRUCTION MANUAL.
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 16 OF 24
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 18 OF 24
PRESS TAPE
FIGURE 17
HEATER LINE
(EVAP TO WATER PUMP)
09153-PCH
PASS. SIDE
(EVAP. BRKT)
64355-PCB
TWIST WITH
THIS
WRENCH
LUBRICATE O-RING
(SEE FIGURES 10 &
11, PAGE 12)
FIGURE 8
HOLD WITH
THIS WRENCH
1/4-20 x 1/2”
BOLT
(LOCATED ON
SUB CASE)
#10 O-RING
(33589-VUF)
DRIVER SIDE
(EVAP. BRKT)
64354-PCB
#6 LIQUID LINE
(09150-PCL)
ECU MODULE
1/4-20 x 1/2”
BOLT
(LOCATED ON
SUB CASE)
GEN IV 1955-56 CHEVY
EVAPORATOR HARD LINE INSTALLATION
HEATER LINE
(EVAP TO INTAKE)
09152-PCH
#6
O-RING
(33857-VUF)
#10 O-RING
(33859-VUF)
#10 SUCTION
LINE
(09151-PCS)
# 10 SUCTION LINE
WRAP ALL EXPOSED METAL
(FITTINGS & TUBE)
WITH SUPPLIED
PRESS TAPE.
NOTE: AFTER INSTALLING
18
GEN IV 1955-56 CHEVY
#2
A/C-HEAT
BLEND
STEPPER
#3
N/A
N/A
BLACK
A/C-HEAT
BLEND
STEPPER
#3
BSC
THERMISTOR
PROBE
YELLOW
BLACK
BLACK
BLACK
WHITE
RED
WHITE
BSC
(BLOWER
SPEED
CONTROL)
L1
H1
(1) MODE
SELECTOR
SWITCH
BLACK
BLACK
12 ga RED
AC
COMP
16 ga BLUE
BLOWER
TO BATTERY
(+)
(POSITIVE TERMINAL)
OR BATTERY
TERMINAL ON
STARTER
SOLENOID
WARNING: DO NOT
CONNECT AUXILIARY
DEVICES TO THE
COMPRESSOR LEAD.
THIS WILL RESULT
IN SEVERE DAMAGE
TO SYSTEM!
COMP
SAFETY
SWITCH
TO
COMPRESSOR
BLUE
HEATER
CONTROL
VALVE
12 ga RED
30 AMP
CIRCUIT
BREAKER
RED
( )
ORANGE
RED
TO BATTERY
86
85
(NEGATIVE TERMINAL)
H2
B2 M2 AC2
L2
(2) BLOWER
SPEED
SWITCH
HCV
WHITE
16 ga GREEN
CHASSIS
GROUND
WHITE
86
85
B1 M1 AC1
THERMISTOR
PROBE
N/A
( )
TO
IGNITION
TO BATTERY
(NEGATIVE TERMINAL)
RED
WHT/BLU
WHT/RED
WHITE/YELLOW
WHITE/GREEN
20 ga BLUE
20 ga GREEN
N/A
N/A
COLD
DEFROST
STEPPER
#2
#1
DEFROST
STEPPER
A/C-HEAT
STEPPER
#1
A/C-HEAT
STEPPER
ECU
TOP VIEW
(ELECTRONIC CONTROL
UNIT)
20 ga GRAY
20 ga ORANGE
48” 20 ga VIOLET
20 ga YELLOW
20 ga WHITE
20 ga RED
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 19 OF 24
19
HOT
GEN IV 1955-56 CHEVY
OPERATION OF CONTROLS
FOR MAXIMUM COOLING AND HEATING, THE AIR LEVER MUST BE IN “INSIDE MODE” POSITION
NOTE: WHEN BATTERY POWER IS FIRST CONNECTED TO THE ECU, THE COMPUTER GOES THROUGH AN
INITIALIZATION SEQUENCE. THIS INITIALIZATION MAY TAKE UP TO 30 SECONDS. DURING INITIALIZATION THE
BLOWER WILL NOT OPERATE, BUT THE DOORS INSIDE THE UNIT WILL BE OPERATING. A LOW BATTERY OR
DISCONNECTING THE BATTERY MAY ALSO TRIGGER A RE-INITIALIZATION. DURING START UP, A LOW BATTERY MAY
DROP BELOW 7 VOLTS, TRIGGERING RE-INITIALIZATION.
BLOWER
SPEED
MODE
DOOR
LEVER
A/C
THERMOSTAT
A/C MODE
SYSTEM OFF
OFF
FAN
DASH
FLOOR
C
O
T
L
E
D
M
HI
DEF
H
E
A
E
T
F
MODE LEVER
INFINITELY VARIABLE FROM DASH TO
FLOOR TO DEFROST
FAN
DASH
FLOOR
C
O
T
LE
D
M
HI
DEF
H
E
AE
TF
HOT
HOT
HEAT MODE
OFF
FAN
DASH
FLOOR
C
O
T
EL
D
M
OFF
COLD
COLD
TEMP
BLEND
DOOR
LEVER
A/C THERMOSTAT
IN A/C AND DE-FOG
MODE THIS LEVER SHOULD
BE UP. FOR HEAT THIS LEVER
SHOULD BE DOWN
HI
BLOWER SPEED
THIS LEVER CONTROLS
THE BLOWER SPEED,
WHICH IS INFINITELY VARIABLE
FROM OFF TO HI
DEF
H
E
A
E
T
F
FAN
DASH
FLOOR
C
O
T
L
E
D
M
HI
DEF
H
E
A
E
TF
HOT
HOT
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 20 OF 24
OFF
COLD
COLD
TEMP BLEND LEVER
1.THIS LEVER SHOULD BE
FULLY UP WHEN IN
AIR CONDITIONING
POSITION.
2.IN ANY MODE
THE TEMPERATURE
CAN BE VARIED BY
PUSHING THE
TEMPERATURE LEVER
DOWN. ALL THE WAY
DOWN IS FULL HOT.
DEFROST MODE
20
GEN IV 1955-56 CHEVY
TROUBLE SHOOTING
INFORMATION
SOLUTION
SYMPTOM
BLOWER STAYS ON HIGH, NO
MODE FUNCTIONS
BE SURE CONTROL HEAD
CONNECTOR IS PROPERLY
INSTALLED
PARTIAL FUNCTION OF CONTROL
HEAD. (SOME FUNCTIONS WORK)
CHECK FOR DAMAGE TO
CONTROL HARNESS
COMPRESSOR DOES NOT TURN
ON. (ALL OTHER FUNCTIONS WORK)
CHECK FOR PROPER CHARGE
BE SURE AC LEVER (SECOND FROM
LEFT) IS UP.
NO FUNCTION AT ALL
CHECK MAIN POWER LEAD AFTER
CIRCUIT BREAKER
CHECK FOR POWER WITH IGNITION
ON AT PURPLE WIRE
CHECK ALL GROUNDS
21
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 21 OF 24
GEN IV 1955-56 CHEVY
THERMOSTAT ADJUSTMENT
OFF
FAN
DASH
FLOOR
C
O
T
EL
D
M
HI
THERMISTOR
PROBE
DEF
H
E
A
E
T
F
EVAP.
COLD
PLASTIC
TOP VIEW
HOT
ADJUST THIS
LEVER UP
OR DOWN TO
REGULATE
TEMPERATURE
NOTE: GEN IV UNITS DO NOT HAVE A REMOTE THERMOSTAT.
THE THERMISTOR PROBE INSTALLED IN THE EVAPORATOR SERVES
AS THE THERMOSTAT WHICH IS CONTROLLED BY THE
COLD/OFF LEVER ON THE CONTROL PANEL
AIR CONDITIONING ADJUSTMENTS:
THE AIR CONDITIONER THERMOSTAT LEVER(COLD LEVER) CONTROLS COIL TEMPERATURE.
ADJUSTING THE LEVER UP MAKES THE SYSTEM OPERATE COLDER. IF THE THERMOSTAT LEVER IS SET TOO COLD THE EVAPORATOR
MAY "ICE UP" UNDER HIGH HUMIDITY CONDITIONS- THE EVAPORATOR COIL IS RESTRICTED WITH ICE AND COLD AIR FLOW WILL
BE REDUCED.
ADJUSTING THE LEVER DOWN MAKES THE SYSTEM OPERATE WARMER. THE COMPRESSOR CLUTCH WILL CYCLE MORE FREQUENTLY
AND THE A/C SYSTEM WILL NOT GET AS COOL AS IT COULD.
OPTIMUM PERFORMANCE WILL BE ATTAINED WITH THE THERMOSTAT ADJUSTED AS COLD AS POSSIBLE WITHOUT “ICING UP” THE
COIL AND THEN USING THE TEMP/BLEND LEVER (OFF/HEAT) TO ADJUST VENT TEMPERATURE.
ADJUSTING A/C THERMOSTAT
1.) SYMPTOM: THE A/C WORKS WELL AT FIRST THEN QUITS COOLING. THE AIR FLOW FROM THE VENTS IS LOW AND THE COMPRESSOR
CYCLES INFREQUENTLY.
SOLUTION: THE THERMOSTAT LEVER IS SET TOO COLD , THE EVAPORATOR IS "ICING UP" AND RESTRICTING AIR FLOW. ALLOW
THE ICE TO MELT BY MOVING THE THERMOSTAT LEVER DOWNWARD (WARMER) IN INCREMENTS OF 10% UNTIL SYMPTOMS
DIMINISH.
2.) SYMPTOM: A/C NEVER GETS COLD AND THE COMPRESSOR CLUTCH CYCLES FREQUENTLY.
SOLUTION: THE THERMOSTAT LEVER IS SET TOO WARM. ADJUST THE THERMOSTAT LEVER UPWARD (COLDER) IN INCREMENTS OF
10% UNTIL THE COMPRESSOR CLUTCH CYCLES INFREQUENTLY. AVOID SETTING THE THERMOSTAT LEVER TOO COLD.
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 22 OF 24
22
2-3/8”
2-1/8”
1/2”
3-9/16”
PASSENGER SIDE FENDER
CORE SUPPORT
TEMPLATE
2-1/4”
2-5/16”
1-1/4” DIAMETER
EXISTING
HOLES
5/16” DIAMETER
23
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 23 OF 24
FOLD PAGE AT THIS LINE AND POSITION AT EDGE OF CORE SUPPORT (REMOVABLE PANEL)
(TOP)
2-3/4”
GEN IV 1955-56 CHEVY
EVAPORATOR KIT
56155-PCZ
EVAPORATOR KIT PACKING LIST
No.
1.
2.
QTY.
PART No.
1
1
760155-VCE
78255-PCN
DESCRIPTION
1955-56 CHEV. EVAP. SUB CASE
1955-56 CHEV. CAR WO AC ACC. KIT
CHECKED BY:
PACKED BY:
DATE:
1
1955-57 CHEVY EVAP.
SUB CASE 760155-VCE
2
DASH
C
O
L
D
ACCESSORY KIT
78255-PCN
906155-PCZ REV A 4/4/05, GEN IV ‘55-’56 CHEVY INSTRUCTIONS PG 24 OF 24
FLOO
R
DEF
H
E
A
T